6.19 Program SW4 Function (TX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “” button to enter SW4 setting.
3) Press “” and “” button to scroll and select between settings.
4) Exit Program SW4 Function by pressing the “BACK” button until the cursor is
shown next to “SW4FUNC”.
5) Press “” and “” button to scroll through other Flex 2JX settings.
Button: Select “NORMAL” for momentary output relay contact and “TOGGLE” for transmitter
toggled output relay contact. Select “AB” or “0AB” or “ABAB” or “0ABAB” for
Select A/B, off/A/B, A/B/AB or off/A/B/AB output relay contacts. Select “ABC” or “0ABC”
adds the 3
rd
output for Select A/B/C output relay contacts (see section 6.25~6.26).
Rocker Switch: Select “NORMAL” for 2-stage On-On or 3-stage On-Off-On output relay contacts.
Select “SW AABB” for Select A/A+B/B output relay contacts. Select “ABC” or
“0ABC” adds the 3
rd
output for Select A/B/C output relay contacts (see section 6.25~6.26).
Important: If SW4 is set to one of the above settings then the SW1 output relay function in
receiver must set to “NORMAL” or “ABUS” (Reversed Logic A/A+B/B).
6.20 Program SW5 Function (TX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “” button to enter SW5 setting.
3) Press “” and “” button to scroll and select between settings.
4) Exit Program SW5 Function by pressing the “BACK” button until the cursor is
shown next to “SW5FUNC”.
5) Press “” and “” button to scroll through other Flex 2JX settings.
Button: Select “NORMAL” for momentary output relay contact and “TOGGLE” for transmitter
toggled output relay contact. Select “AB” or “0AB” or “ABAB” or “0ABAB” for
Select A/B, off/A/B, A/B/AB or off/A/B/AB output relay contacts. Select “ABC” or “0ABC”
adds the 3
rd
output for Select A/B/C output relay contacts (see section 6.25~6.26).
Rocker Switch: Select “NORMAL” for 2-stage On-On or 3-stage On-Off-On output relay contacts.
Select “SW AABB” for Select A/A+B/B output relay contacts. Select “ABC” or
“0ABC” adds the 3
rd
output for Select A/B/C output relay contacts (see section 6.25~6.26).
Important: If SW5 is set to one of the above settings then the SW1 output relay function in
receiver must set to “NORMAL” or “ABUS” (Reversed Logic A/A+B/B).
6.21 Program SW6 Function (TX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “” button to enter SW6 setting.
3) Press “” and “” button to scroll and select between settings.
4) Exit Program SW6 Function by pressing the “BACK” button until the cursor is
shown next to “SW6FUNC”.
5) Press “” and “” button to scroll through other Flex 2JX settings.
Button: Select “NORMAL” for normal momentary relay output and “TOGGLE” for transmitter
toggled relay output.