Page 23
6.19 Program SW4 Function (TX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “→” button to enter SW4 setting.
3) Press “↑” and “↓” button to scroll and select between settings.
4) Exit Program SW4 Function by pressing the “BACK” button until the cursor is
shown next to “SW4FUNC”.
5) Press “↑” and “↓” button to scroll through other Flex 2JX settings.
Button: Select “NORMAL” for momentary output relay contact and “TOGGLE” for transmitter
toggled output relay contact. Select “A→B” or “0→A→B” or “A→B→AB” or “0→A→B→AB” for
Select A/B, off/A/B, A/B/AB or off/A/B/AB output relay contacts. Select “A→B→C” or “0→A→B→C”
adds the 3
rd
output for Select A/B/C output relay contacts (see section 6.25~6.26).
Rocker Switch: Select “NORMAL” for 2-stage On-On or 3-stage On-Off-On output relay contacts.
Select “SW A→AB→B” for Select A/A+B/B output relay contacts. Select “A→B→C” or
“0→A→B→C” adds the 3
rd
output for Select A/B/C output relay contacts (see section 6.25~6.26).
Important: If SW4 is set to one of the above settings then the SW1 output relay function in
receiver must set to “NORMAL” or “ABUS” (Reversed Logic A/A+B/B).
6.20 Program SW5 Function (TX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “→” button to enter SW5 setting.
3) Press “↑” and “↓” button to scroll and select between settings.
4) Exit Program SW5 Function by pressing the “BACK” button until the cursor is
shown next to “SW5FUNC”.
5) Press “↑” and “↓” button to scroll through other Flex 2JX settings.
Button: Select “NORMAL” for momentary output relay contact and “TOGGLE” for transmitter
toggled output relay contact. Select “A→B” or “0→A→B” or “A→B→AB” or “0→A→B→AB” for
Select A/B, off/A/B, A/B/AB or off/A/B/AB output relay contacts. Select “A→B→C” or “0→A→B→C”
adds the 3
rd
output for Select A/B/C output relay contacts (see section 6.25~6.26).
Rocker Switch: Select “NORMAL” for 2-stage On-On or 3-stage On-Off-On output relay contacts.
Select “SW A→AB→B” for Select A/A+B/B output relay contacts. Select “A→B→C” or
“0→A→B→C” adds the 3
rd
output for Select A/B/C output relay contacts (see section 6.25~6.26).
Important: If SW5 is set to one of the above settings then the SW1 output relay function in
receiver must set to “NORMAL” or “ABUS” (Reversed Logic A/A+B/B).
6.21 Program SW6 Function (TX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “→” button to enter SW6 setting.
3) Press “↑” and “↓” button to scroll and select between settings.
4) Exit Program SW6 Function by pressing the “BACK” button until the cursor is
shown next to “SW6FUNC”.
5) Press “↑” and “↓” button to scroll through other Flex 2JX settings.
Button: Select “NORMAL” for normal momentary relay output and “TOGGLE” for transmitter
toggled relay output.