Page 24
6.22 Program SW7 Function (TX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “” button to enter SW7 setting.
3) Press “” and “” button to scroll and select between settings.
4) Exit Program SW7 Function by pressing the “BACK” button until the cursor is
shown next to “SW7FUNC”.
5) Press “” and “” button to scroll through other Flex 2JX settings.
Button: Select “NORMAL” for normal momentary relay output and “TOGGLE” for transmitter
toggled relay output.
6.23 Program Channel Scanning Function (RX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “” button to enter Channel Scanning setting.
3) Press “” and “” button to scroll and select between settings.
4) Exit Program Channel Scanning Function by pressing the “BACK” button until
the cursor is shown next to “CH SCAN”.
5) Press “” and “” button to scroll through other Flex 2JX settings.
Select “01” the receiver only scans the channel set on the receiver.
Select “02” the receiver scans the channel set on the receiver plus the next channel up (scans
channel N and channel N+1).
Select “03” the receiver scans the channel set on the receiver plus the next two channels
up (scans channel N, channel N+1 and channel N+2).
Select “ALL” the receiver scans all 62 channels.
6.24 Program MAIN Relay Function (RX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “” button to enter MAIN Relay setting.
3) Press “” and “” button to scroll and select between Test and Normal.
4) Exit Program MAIN Relay Function by pressing the “BACK” button until
the cursor is shown next to “MAIN RLY”.
5) Press “” and “” button to scroll through other Flex 2JX settings.
Select “NORMAL” for normal operation (receiver mains and all other outputs enabled).
Select “TEST” for system testing (receiver mains disabled and all other outputs enabled).