6.44 Program SW6 Output Relay (RX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “” button to enter SW6 Output Relay setting.
3) Press “” button and then “” and “” button to select “LOCK” or “UNLOCK”.
4) Press “BACK” button to go back to step 3.
5) Press “” button and then “” button select SW6 Output Relay function.
6) Press “” and “” button to scroll and select.
7) Exit Program SW6 Output Relay by pressing the “BACK” button until the
cursor is shown next to “SW6 RLY”.
8) Press “” and “” button to scroll through other Flex 2JX settings.
UNLOCK Settings (SW6 and SW7 output relays not interlocked):
Select “NORMAL” the output relay becomes momentary contact.
Select “NORMAL+S” the output relay becomes momentary contact. Must press the green
START button together to work.
Select receiver “TOGGLE” the output relay becomes toggled contact.
Select receiver “TOGGLE&E” the output relay becomes toggled contact affected by the e-stop
command (output relay opens when e-stop button is pressed).
Select “PITCH” SW6 button becomes the “Pitch” function in Pitch & Catch Operation.
Select “PITCH&E” SW6 button becomes the “Pitch” function in Pitch & Catch Operation. When
Pitch command is initiated the receiver mains are disconnected.
Select “STOP” SW6 button becomes an auxiliary e-stop function. Press to disconnect the
receiver mains and press START button to reconnect the receiver mains.
Important note 1: When one of the above is selected make sure the same SW6 button function
on transmitter is set to “NORMAL”.
Important note 2: When select Pitch & Catch function make sure you set the spare transmitter
to the next channel up and the receiver channel scanning to “02”.
LOCK Settings (SW6 and SW7 output relays interlocked):
Select “NORMAL” both output relays become interlocking momentary contacts.
Select receiver “TOG/TOG” both output relays become interlocking toggled contacts.
Select receiver “TOG/TOG&E” both output relays become interlocking toggled contacts affected
by the e-stop command (output relay opens when e-stop button is pressed).
Select “ON/OFF” both output relays become interlocking On and Off contacts.
Select “ON/OFF+S” both output relays become interlocking On and Off contacts. Must press
the green START button along with the On or Off button to work.
Select “ON/OFF&E” both output relays become interlocking On and Off contacts affected by the
e-stop command (output relay opens when e-stop button is pressed).
Select “MAGNET” the two output relays become interlocking Magnet ON and OFF contacts.
Important note: When one of the above is selected make sure the same SW6 and SW7 button
function on transmitter are both set to “NORMAL”.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Magnetek FLEX BASE and is the answer not in the manual?

Magnetek FLEX BASE Specifications

General IconGeneral
BrandMagnetek
ModelFLEX BASE
CategoryController
LanguageEnglish

Related product manuals