Page 48
8.12 Program Function Relay 2 / K26 Relay (RX)
1) Press “→” button to enter Function Relay 2 setting.
2) Press “↑” and “↓” button to scroll and select.
3) Exit Program Function Relay 2 by pressing the “BACK” button until the
cursor is shown next to “FUNC RLY2”.
4) Press “↑” and “↓” button to scroll through other Flex BASE settings.
--- : START function only.
LV : Function relay closes when receiver voltage is low.
ID : Function relay works simultaneously with all motion commands.
NORMAL : START function + AUX with normal momentary output.
TOGGLE : START function + AUX with toggled/latching output.
TOG&E : START function + AUX with toggled/latching output. The relay opens when
STOP button is pressed down and transmitter power off.
EXT : FUNCTION relay works simultaneously with the receiver MAIN relays.
TDM A+B : FUNCTION relay closes when selector switch is rotated to the A+B position
and opens when rotate to A or B positions (tandem monitoring output).
HORN : FUNCTION relay closes for up to 3 seconds when Start command is initiated at
transmitter power on and then becomes normal momentary outputs thereafter.
RS : For RS system, the function relay works simultaneously with the Select pushbutton.
8.13 Program Function Relay 3 / K30 Relay (RX)
1) Press “→” button to enter Function Relay 3 setting.
2) Press “↑” and “↓” button to scroll and select.
3) Exit Program Function Relay 3 by pressing the “BACK” button until the
cursor is shown next to “FUNC RLY3”.
4) Press “↑” and “↓” button to scroll through other Flex BASE settings.
--- : START function only.
LV : Function relay closes when receiver voltage is low.
ID : Function relay works simultaneously with all motion commands.
NORMAL : START function + AUX with normal momentary output.
TOGGLE : START function + AUX with toggled/latching output.
TOG&E : START function + AUX with toggled/latching output. The relay opens when
STOP button is pressed down and transmitter power off.
EXT : FUNCTION relay works simultaneously with the receiver MAIN relays.
TDM A+B : FUNCTION relay closes when selector switch is rotated to the A+B position
and opens when rotate to A or B positions (tandem monitoring output).
HORN : FUNCTION relay closes for up to 3 seconds when Start command is initiated at
transmitter power on and then becomes normal momentary outputs thereafter.
RS : For RS system, the function relay works simultaneously with the Select pushbutton.