ARM DOWN SENSORS SETTINGS
-- Set the telescope to the down position, ensuring the control is
activated for as long as necessary, keeping the access platform
switched on.
ACCESS PLATFORM 120 AETJL
- Loosen the lock nuts (1, 080 - 108).
- Screw or unscrew the sensors (2, 080 - 108) until their LED, located
next to the power supply wire, switches from o to on (orange);
the clearance remaining between the support and the sensor is
approximately 3 mm (0.11 in).
- Tighten the lock nuts.
ACCESS PLATFORMS 150 AETJC, 150 AETJC 3D, 150 AETJL, 170
AETJL, AETJ 43, AETJ 43 3D, AETJ 49
-Remove the sensor protective covers from arm 3 (1, 080 - 109).
- Loosen the lock nuts (1, 080 - 110).
- Screw or unscrew the sensors (2, 080 - 110) until their LED, located
next to the power supply wire, switches from o to on (orange);
the clearance remaining between the support and the sensor is
approximately 3 mm (0.11 in).
- Tighten the lock nuts.
Checking
Retracted telescope sensor SQ4a Measure using the calibrator Multimeter
Telescope LED status Wire N° Menu Description Message Display
Retracted* Orange 118
1.3.12 Tele sw
Closed 0V
Extended Not lit 118 Open ~V
Retracted telescope sensor SQ4b Measure using the calibrator Multimeter
Telescope LED status Wire N° Menu Description Message Display
Retracted* Orange 245
1.3.15 Tele sw
Closed 0V
Extended
* Access platform in transport position.