ELECTRICITY
114
80
547379EN
80 (08/03/2017)
Base module control unit Measure using the calibrator Multimeter
Connector PIN Wire N° Signal Menu Description Not activated Activated Not activated Activated
D-OUT
1 325 Turret rotation NOT MEASURABLE 0V
2
328
Arm 1/2
NOT MEASURABLE
0V
3 327 Arm 3 NOT MEASURABLE 0V
4 322 Telescope NOT MEASURABLE 0V
5
321
Jib
NOT MEASURABLE
0V
6 324 JIB Rotation NOT MEASURABLE 0V
7 323 Compensation NOT MEASURABLE 0V
8
326
Basket rotation
NOT MEASURABLE
0V
9 Free NOT MEASURABLE
10 Free NOT MEASURABLE
11
Free
NOT MEASURABLE
12 Free NOT MEASURABLE
13 329 Traveling NOT MEASURABLE 0V
14
331
Alarm/faults
NOT MEASURABLE
_ (4)
15 320 Buzzer NOT MEASURABLE _ (5)
16 330 Tilt NOT MEASURABLE _ (6)
17
NOT MEASURABLE
18 335 Overload ref. NOT MEASURABLE _ (7)
19 338 Maintenance alarm NOT MEASURABLE 0V
20
NOT MEASURABLE
21 336 Overload NOT MEASURABLE _ (7)
22 338 Tilt ref. NOT MEASURABLE not used
23
Free
NOT MEASURABLE
24 Free NOT MEASURABLE
1 - (680.3.6 MANIPULATOR  OPERATION AND SETTINGS, 5 133)
2 - See overload settings (680.3.5 SAFETY COMPONENTS  CONTROL AND SETTINGS, 5 126)
3 - Keep the selection to measure the signal.
4 - Negative signal (0 V) intermittent: LED overload.
5 - Negative signal (0 V) intermittent if in tilt, continue if overload.
6 - Negative signal (0 V) intermittent (tilt LED + variable speed controller redundancy).
7 - See overload (680.3.5 SAFETY COMPONENTS  CONTROL AND SETTINGS, 5 126)
8 - Joystick in neutral position if parameter displayed is Open.
Each time the joystick is moved, the parameter turns to Closed.
9 - The operation of the base and basket failsafes is checked using input 2.4.5 (680.3.4 VARIABLE SPEED
CONTROLLERS  CONTROL AND SETTINGS, 5 115)
10 - Based on the position of the selector at the time of the check.
NOTE:
- When powered on, the LED ashes once, then switches on or remains o depending on the results of
the test phase.
- There are no parameters for displaying the outputs of the basket module control unit, measurements
must be taken with a multimeter.
ELECTRONIC MODULES  DIAGNOSTICS AND SETTINGS
(680.3.4 VARIABLE SPEED CONTROLLERS  CONTROL AND SETTINGS, 5 115)