80.5.2 ZIVAN BATTERY CHARGER ERROR SIGNALS
SYMPTOMS CAUSES TO BE DONE IMMEDIATELY CAUSES TO CHECK
Acoustic signal +
RED LED ashing
Battery disconnected or not
compliant.
Check the connection or the rated
voltage.
Output fuse and if the battery has
been connected with the correct
polarities
Acoustic signal +
YELLOW LED ashing
Temperature probe disconnected
during recharging or out of
operational range.
Check the connection of the
probe and measure the battery
temperature.
The voltage on the temperature
probe and measure the
temperature of the battery.
Acoustic signal +
GREEN LED ashing
Phase 1 and/or Phase 2 more than
the maximum permitted.
Check the capacity of the battery.
Does the charge curve for the
battery comply with that of the
battery charger?
Acoustic signal +
RED-YELLOW LED ashing
Loss of control of output current Logic control unit fault. Stage of reading current or shunt.
Acoustic signal +
RED-YELLOW LED ashing
Loss of control of output voltage
Battery disconnected or fault on
logic control unit.
Stage of reading voltage or
resistance of reading voltage of
open battery.
Acoustic signal +
YELLOW-GREEN LED ashing
An unavailable conguration has
been selected.
Check the position of the selector.
Acoustic signal +
RED-YELLOW-GREEN LED ashing
Over-heating of semi-conductors.
Check the operation of the
ventilation system.
Operation of the fan, fan pilot
circuit, good connections with PTC
sensor.
80.5.3 IES BATTERY CHARGER
SYMPTOMS CAUSES TO BE DONE IMMEDIATELY CAUSES TO CHECK
RED LED ashing
Battery temperature high Ambient temperature > 65°C
Battery element in short circuit
Disconnect the charger from the
mains
Battery condition
Power supply connector
Mains voltage
Select the voltages on the charger
Charger defective
Charge cycle greater than 20 hours
Disconnect/Reconnect the charger
to the mains