ELECTRICITY
126
547379EN
80 (08/03/2017)
80.3.5 SAFETY COMPONENTS CONTROL AND SETTINGS
SWITCHES LOCATION
- (680.2.2 ELECTRICAL POWER COMPONENTS LOCATION, 5 84)
TILT SENSOR SETTINGS
CAUTION
The tilt sensors are pre-congured by the manufacturer.
The only parameter that can be adjusted is sensor initialization.
- Place the access platform on level ground and leave the power
switched on.
- Open the right-hand turret cover (1, 080 - 106).
- Locate the tilt sensor located between the base control panel
box and the counterweight.
CAUTION
Check that the angle of the sensor written in (2, 080 - 107) matches that of the manufacturer's plate
on the machine.
- Take the disconnected wire (2, 080 - 107) protruding from the
sensor.
- Take o the plastic cap (3, 080 - 107) at the end of the wire.
- Remove the right-hand battery protective cover (2, 080 - 107).
- Take an electric wire 0.5 m (19.69 in) long with its ends stripped,
connect it to the wire (2, 080 - 107) and connect it to the – terminal
of the right-hand battery (3, 080 - 106):
- The green LED located under the sensor should ash several times.
- It stops when the sensor has initialized.
- It remains continuously lit.
CAUTION
During normal operation, the green LED is lit, and only switches o if the angular tilt value
is exceeded.
Checking
Tilt sensor
Audible signal
Measure using the calibrator Authorized movements Multimeter
Tilt LED status Menu Description Message Transport position Working position Signal wire
< 3° Lit None
1.3.10 Tilt switch
CLOSED
Travelling
Lifting/lowering
Travelling
Lifting/lowering
0V
> 3°
80 - 106
1
2
80 - 107
1
2
3
WHITE 0 V
BROWN +24 V
YELLOW SIGNAL
Tilt <3° = 0 V
Tilt > 3° = No signal