80.3.6 MANIPULATOR OPERATION AND SETTINGS
MANIPULATOR TESTS USING CALIBRATOR
CAUTION
The manipulator test from the basket base requires the presence of two operators.
- Connect the calibrator to the access platform and display test
menu 2-4 (680.3.4 VARIABLE SPEED CONTROLLERS CONTROL AND
SETTINGS, 5 115)
- Switch on the access platform.
- Climb into the basket, then perform the following actions:
- Move the manipulator (1, 080 - 114) forwards and then backwards
without operating the trigger (2, 080 - 114).
- Press the upper left-hand button then the upper right-hand
button (3, 080 - 114) without operating the trigger.
- Operate the trigger (2, 080 - 114) on its own.
- For each action, check on the sub-menu in question the status of
the inputs/outputs at the neutral point, then when the manipulators
or switches are operated.
TEST
- Lastly, select menu 2-4-1 and 2-4-3 (UPPER BOX TEST) on the calibrator and check:
- That the proportional signal progresses steadily (i.e. from 0 to 100%).
- That it is at 0% in neutral and 100% only when the manipulator almost reaches its limit.
Manipulator test when lifting/lowering and travelling (Y)
Calibrator (measurement) Position of Joystick
Menu
2.4.1 Y-axis voltage % 100 0 100
2.4.2 Y Axis joystick voltage 45 25 5
1.3.1
1.3.2 Accelerator Voltage 45 25 5
* Manipulateur au maximum
Manipulator test with turret/basket rotation (X)
Calibrator (measurement)
Menu Description Left* Neutral Right*
2.4.3 X Axis Joystick % 100 0 100
2.4.4
* Manipulateur au maximum