EasyManua.ls Logo

Manitou AETJ 43 - Page 145

Manitou AETJ 43
286 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ELECTRICITY
142
80
547379EN
80 (08/03/2017)
Led Message Message Description and
Investigations
Variable Speed
Controller
Hour meter Calibrator Comments
12 Flashs
CANBUS
F05005 Can Bus Fault There is no dialog between one or
more electronic control units.
- Check for each of the electronic control units if their LED is
permanently on:
• If all of the LEDs are lit: perform tests §1-1 and §1-2.
• If at least one LED is switched o: perform test §2.
1-1 Tests to be performed 5 BUS-CAN connectors connected.
- Access platform switched on: measure the voltage between the
BUS-CAN wires and the negative (wire 103).
BUS-CAN wire
Theoretical voltage
(V)
The signal must be
between
112 ~2.4V 2.3V < < 2.7V
113 ~2.6V 2.3V < < 2.7V
- Access platform switched o: measure the resistance of the BUS-CAN
circuit between wires 112 and 113 at the diagnostics plug:
The resistance is 95 .
Disconnect successively
Theoretical resistance
between wires 112/113
Smart view
118 
Base control unit 156 
Safety control unit 235 
Variable speed controller
470 
Basket control unit ---
- Access platform switched o: for each of the electronic control
units, measure the resistance between the 112 and 113 inputs
attheCAN connector:
The resistance is 470 .
1-2 Tests to be performed 5 BUS-CAN connectors disconnected.
- Disconnect the BUS-CAN harnesses (wires 113 and 112) at each
end (variable speed controller, base electronic control unit, basket
electronic control unit).
- For wires 113 and 112, check the continuity between each of them and
each end: check that there is no continuity between wires 113 and 112.
- Check the connections, the shielding (variable speed controller
section - BASE box).
- Put the contact bomb on the BUS-CAN connections, bypass the
BUS-CAN lines with external wires to determine if the wires or
connections are defective.
2-Test to be performed if at least one LED is switched o
- Check when switched o if the LED ashes for 0.5 seconds:
• Check the power supply between terminals B+, B+2 (positive
terminals) and B/NEG, C/NEG, D/NEG (negative terminals) of the
control unit which is causing the problem.
• Check the connections of all power supplies mentioned above
- Check the quality of the battery negative signal: wire no. 103.
• Ensure that all of the connections of wire 103 are correctly
attached and connected (crimping of wires not damaged, quality
of contacts, etc.) in the electrical sockets, the terminal blocks, the
terminals, etc.
- Check the quality of the battery positive signal: wire no. 106.
• Ensure that all of the connections of wire 106 are correctly
attached and connected (crimping of wires not damaged, quality
of contacts, etc.) in the electrical sockets, the terminal blocks, the
terminals, etc.

Table of Contents