ELECTRICITY
130
547379EN
80 (08/03/2017)
Overload test
- Of the load still in the basket, take out 20 kg (44 lbs) and check that:
- The alarm switches o.
- The calibrator displays CLOSED in test menu 1.3.16 (SQ5a).
- The calibrator displays OPEN in test menu 2.4.9 (SQ5b).
- Replace the 20 kg (44 lbs), the alarm triggers (permanent tone), tighten the lock nuts (1, 080 - 113)
and put a paint mark on them to conrm the conguration.