EasyManua.ls Logo

Manitou AETJ 43 - Page 265

Manitou AETJ 43
286 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ELECTRICITY
124
80
547379EN
80 (08/03/2017)
TEST MENUS
Menu Traction Status Status (Variable Speed Controller) Mini display Maxi display Pitch Log. Info
1.2.1
Battery Voltage
Battery voltage
0 V
127 V
0.1
+
1.2.2 Armature Motor Voltage Armature Voltage 0 V 127 V 0.5
1.2.3 Field Motor Voltage Field voltage 0 V 127 V 0.5
1.2.4
Armature Motor Current
Armature current
0
625 A
0.20833333
+
1.2.5 Field Motor Current Field current 0 64 A 0.25 +
1.2.6 Armature MOSFET Voltage MOSFET voltage 0 V 127 V 0.5
1.2.7
Controller Temp.
Temperature variable speed controller
-30 °C (-22 °F)
+225 °C (+437 °F)
1
+ –
1.2.8 Capacitor Voltage Capacitor Voltage 0 V 127 V 0.5
1.2.9 Speed estimation Speed measurement 0 1 0.005
1.2.10
Speed estimation
Speed measurement
0 Km/H (0 mph)
60 Km/H (37.28 mph)
1.0
1.2.11 Speed estimation Speed measurement 0 MPH 60 MPH 1.0
1.2.12 Key Switch Hours Count Hour meter operation 0 Hrs 65279.9 Hrs 0.1
1.2.13
Traction Pulsing Hours Count
(Drive)
Hour meter travel 0 Hrs 65279.9 Hrs 0.1
1.2.14 CAN fail node CAN fault note: 2 None
Output,
EOutput
n/a
1.2.15 CAN error count CAN meter error - - -
1.2.16 CAN error code CAN coding error - - -
Service Log Reset
RAZ memory faults
Press + then - to reset Service Log
Menu Traction Test Variable speed controller Mini display Maxi display Pitch Log. Info
1.3.1 Accelerator % Accelerator % 0% 100% 1% range
1.3.2 Accelerator Voltage Accelerator Voltage 0.0 V 5.0 V 0.02 V range
1.3.3
Deadman
Fail-safe
Open
Closed
Switch
1.3.6 Steer left LH steering Open Closed Switch
1.3.7 Steer Right RH steering Open Closed Switch
1.3.8
Horn
Horn
Open
Closed
Switch
1.3.9 Traction select Traction select Open Closed Switch
1.3.10 Tilt Tilt input Open Closed Switch
1.3.11
Boom Rest
Arm down sensor
Open
Closed
Switch
1.3.12 Tele sw. Extended telescope sensor Open Closed Switch
1.3.13 Brake Release Brake sensor released Open Closed Switch
1.3.14
BDI Input
BDI Input
Open
Closed
Switch
1.3.15 Frame Fault Earth detection Open Closed Switch
1.3.16 Cage Ovl2 Overload detection no. 2 Open Closed Switch
1.3.18
Joystick NTRL sw
Contact joystick not neutral
Open
Closed
Switch
1.3.19 LS Traction sw Select low speed traction Open Closed Switch
1.3.20 Ver xxxxxxx Software version xxxxxx xxxxxx
1.3.21
Controller Serial Number
Variable speed controller serial number
0
99999999
1.3.22 Controller type Power type xxnnn
Menu Pump Status Variable speed controller (hydraulic functions) Mini display Maxi display Pitch Log. Info
2.2.1 Battery Voltage Battery voltage 0 V 127 V 0.1 V +
2.2.2
Motor Voltage
Motor Voltage
0 V
127 V
0.5 V
2.2.3 Motor Current Motor Current 0 625 A 0.20833333 +
2.2.4 MOSFET Voltage MOSFET voltage 0 V 127 V 0.5 V
2.2.5 Controller Temp. Microprocessor temperature -30 °C (-22 °F)
+225 °C (+437 °F)
1 °C (33.8 °F) + –
Service Log Reset RAZ memory faults Press + then - to reset Service Log

Table of Contents