31
JIB - BASKET
547379EN
55 (08/03/2017)
JIB BASKET
55.1 JIB BASKET CONTROLS
55.1.1 CHECK THE CLEARANCE OF THE TELESCOPE
CLEARANCE between moving tube and arm of telescope
Lateral
Upper 0.5 mm (0.02 in)
If necessary, add the adjustment plates if necessary (see parts catalogs).
55.2 JIB BASKET REMOVAL
55.2.1 REMOVAL OF PADS OF TELESCOPIC CYLINDER
Remove the telescopic cylinder (6TELESCOPIC CYLINDER REMOVAL,
5 63)
Remove and replace the pads (1, 055 6) (see parts catalog).
55.2.2 REMOVAL OF REAR PADS OF TELESCOPIC CYLINDER
- Remove the telescopic cylinder (6TELESCOPIC CYLINDER REMOVAL,
5 63).
- Release the pads (1, 055 7) by slightly raising the basket.
- Remove the pads (1, 055 7), pay attention to the position and
number of adjustment plates.
- Get new pads (see parts catalog)
- Replace the pads and adjustment plates, then check the clearance
(655.1.1 CHECK THE CLEARANCE OF THE TELESCOPE, 5 31).
55 - 6
1
55 - 7
1
1