HYDRAULIC CIRCUIT DECONTAMINATION
- Let the engine run (accelerator pedal at mid position) for 5 minutes without using
any accessories on the lift truck, then for 5 more minutes while using all the hydraulic
movements (except the steering system and the service brakes).
- Accelerate the engine at full speed for 1 minute, then activate the steering system
and the service brakes.
- This operation allows the circuit to be decontaminated by the hydraulic oil filter.
IMPORTANT
It is sometimes necessary to bleed the circuits at the pump inlet when an air bubble forms during draining.
Then consult your dealer.
CHECK Injection pump *
CHECK Injectors *
CHECK Radiator *
CHECK Water pump and thermostat *
CHECK Alternator and starter *
CHECK Hydrostatic transmission circuit pressures *
CHECK Hydrostatic transmission control flow *
CHECK Hydrostatic transmission / accelerator cut-off operation *
CHECK Steering *
CHECK Kingpins (MC 18-2)
CHECK Wheel motor pivots (MC 18-4)
CHECK Rear axle *
CHECK Disc brake wear on wheel motors *
CHECK Condition of boom assembly *
CHECK Mast lifting chains *
CHECK Mast lifting chain pulleys *
CHECK Mast guide rollers *
CHECK Mast bearing rollers *
CHECK Thickness of the mast wearing plates *
3 - 31
4
647690 (29/01/2019)