Published 3-30-2018, CTRL 636-05 6-17
CD15 OPERATOR MANUAL MAINTENANCE
6
Clean Battery and Cables
1. Open the battery box cover (Figure 6-18).
2. Tighten all battery hardware to keep the battery securely
in place.
3. Disconnect the battery cables.
4. Sprinkle the batteries with baking soda to neutralize the
acid. Rinse with water. Be careful not to get water inside
the battery.
5. Coat the battery posts and the battery cable connections
with battery-terminal protector and reconnect the battery
cables.
6. Coat the frame grounds, the starter connections, and the
alternator connections battery-terminal protector.
7. Close and latch the battery box cover.
Clean the Radiator
NOTE: To inhibit personal injury, always wear safety
glasses when using compressed air.
Clean the radiator fins by using compressed air or a water
hose to remove all foreign materials. If these materials are
1100263
8941
Battery
Disconnect
FIGURE 6-18
Battery
Battery Cable
Connection Diagram
Fuse and Relay
Identification