48 CONTENTS
input behavior of the digital inputs using the DigitalInputThreshold property in "Digital I/O -> DigitalInput-
Threshold":
Figure 5: wxPropView - DigitalInputThreshold
8.2.1.1.2 Characteristics of the digital outputs
U
min
[V] U
max
[V] I
min
[mA] I
max
[mA]
Output 30 100 (on state current)
Figure 6: DigOut mvBlueFOX-xxx
8.2.1.1.3 Connecting flash to digital output
You can connect a flash in series to the digital outputs as shown in the following figure, however, you should only
use LEDs together with a current limiter: