3.4 Programming Hexadecimal Data
Hexadecimal or ’Hex’ digits are often required for a program-
ming item, such as telephone numbers and reporting codes. To
insert a Hex digit into a given entry, press the [*] key to enter the
Hex menu. Use the arrow keys to scroll through the each Hex dig
-
its (A through F). When the desired letter is displayed, press the
[*] key.
Hex digits can also be entered by pressing [*] key followed by the
number from 1-6 corresponding to each Hex letter (A = 1, B = 2,
C = 3, up to F = 6). Once the digit is entered, the control panel will
automatically return to the decimal programming mode.
For example, to enter data ‘ABCD’ on a PC4020 you would
enter: [*], [1], [*], [2], [*], [3], [*], [4]
3.5 Programming Toggle Options
Many programming items are toggle options that are either
enabled or disabled. Use the arrow keys (< >) to scroll through the
toggle options. Press the [*] key to switch back and forth between
[Y]es (enabled) and [N]o (disabled). Once all the toggle options
have been programmed, press the [#] key to save your changes
and return to the previous menu.