37
Ground Start (01)
Any output programmed for ’Ground Start’ can be active from 000
to 255 seconds. The default setting is 000 seconds.
NOTE: The panel will wait until the end of the Ground Start before
dialing. This feature must not be used on UL listed systems.
Chime Pulse (02)
Any output programmed for ’Chime Pulse’ can be active from 000
to 255 seconds. The default setting is 002 seconds.
Duress Pulse (03)
Any output programmed for ’Duress Pulse’ can be active from
000 to 255 seconds. The default value is 005 seconds.
Card Used (04)
Any output programmed for ’Card Used’ can be active from 000
to 254 seconds. The default value is 005 seconds. A pulse time of
000 will cause the output to toggle every time a card is presented.
NOTE: This output will not activate when used with the ‘Wait for
Privileged Card’ feature.