29
NOTE: Only use with Access Codes, no other disarm method will
support this feature. This feature should not be used with hand-held
wireless keypads
8.5 Dual Users For Disarming
If the partition toggle for 'Dual Usr Dis' (section 5.0) is set to
YES, a second access code is required for disarming.
Both codes are logged to the event buffer, but the 2nd code is
sent as the opening.
The 2nd user MUST be assigned to the same partitions as the
1st user.
The 2nd access code must be entered within 120 seconds of
the 1st code otherwise the keypad times out to the idle state.
During Exit Delay and Entry Delay, both user codes are still
required to disarm the area.
When performing a "Disarm All' function via the Global key-
pad, if any of the areas that the user is assigned to require dual
users, a second code will be required. If the second user is
assigned to all the areas being disarmed, then the action will
be performed successfully. If the second user is invalid, then
the areas that require dual users will not be turned off. Only
the areas that are assigned to both users will be disarmed.
When using the 'Disarm All Partitions' in the global keypad
menu, if 'Dual Code' is only enabled on one of the partitions, a
second user code will always be required to disarm all of your
partitions.
NOTE: This feature should not be used with hand-held wireless key-
pads.