11
Section 4: Module Enrollment
4.1 Enrolling Keypads and Modules
Once the wiring of all keypads and modules is complete, they
must be enrolled on the system. Apply power to the system by
first connecting the battery, followed by the AC transformer. All
LCD keypads will display the software version of the keypad.
NOTE: Make sure all power to the system is OFF when connecting
modules.
NOTE: Record the location and number of each module for future
reference.
Enrolling the First Keypad to Partition 1
To enroll the first keypad, go to the keypad that is to be assigned to
Partition 1. Press any key on that keypad. The keypad will beep and
display the message ’45XX Mod. #1’. This keypad will automati
-
cally be assigned to Partition 1.
Once the first keypad has been enrolled, the rest of the system
keypads and modules can be enrolled through the ’Module Hard
-
ware’ section of installer’s programming.
Enrolling All Other Keypads and Modules
Ref # [0200] then scroll to desired module
Enter the following at the keypad you have just enrolled:
1. Enter installers programming by pressing [*] [8] [Installers
Code].
NOTE: The default installers code is [5555].
2. Scroll to Module Hardware and press the [*] key.
3. The message ’Enroll Module’ will appear. Press [*].
4. Scroll through the different modules until the module you
wish to enroll is displayed. Press the [*] key.
LCD45XX Keypads
The keypad will display the message ’Press Any Key On Desired
Unit’. Go to the keypad to be enrolled and press any key. Return
to the original keypad. A message similar to the following will be
displayed to confirm enrollment (e.g. ’LCD45XX Mod 02
Enrolled’).
For keypads: next, you must select which partition the keypad
is to control. Use the arrow keys to scroll to the desired partition
and press the [*] key to select. If the enrolled keypad is slated for
global operation, scroll to Option 00 ’Global’ and press [*].
If you press the [#] key, the keypad will be assigned to Partition 1
by default.
For more information regarding partition and global keypads, see
Section 6: ”Keypad Operation’.
Module Tampers
When enrolling PC4108A, PC4116, PC4204/PC4204CX,
PC4216, PC44XX, PC4702, PC4820, PC4850, PC4164 or alter
-
nate communicator modules, the message ’Create Tamper On
Desired Unit’ will be displayed. The tamper is required for enroll
-
ment.
To create the required tamper, secure the tamper zone on the mod-
ule and then open it. It is this transition from secure to violated
which enrolls the module. After this is done, the keypad will dis
-
play the module number and will confirm enrollment (e.g.
’PC4204/PC4204CX Mod 01 Enrolled’). Record the module
number in the programming worksheets. Once the module is
enrolled, re-secure the tamper.
Zone Expanders
NOTE: Enroll all zone expanders before assigning zones to PC4820
and AML devices.
When enrolling zone expanders (PC4108A, PC4116 and PC4164),
the panel will display ’PC41XX Module’. It does not ask what type
of expander is being enrolled. Once the tamper is created, the con
-
trol panel will automatically indicate the type of expander and will
confirm enrollment (e.g. ’PC4116 Mod 01 Enrolled’).
Zones 1 to 16 are located on the main control panel. Additional
zones are added in sequence. For example, if two PC4108A zone
expanders are enrolled, the first one enrolled will be assigned zones
17 to 24 and the second will be assigned zones 25 to 32.
The system can have a maximum of 128 zones. To confirm which
zones are assigned to which expander, press any key when the
enrollment confirmation message is displayed.
NOTE: Be sure to record the zones assigned to each zone expander
module in the System Overview section of the Programming Work
-
sheets.
The PC4164 is a wireless receiver. When you enroll a PC4164
module, you can enroll up to 64 wireless devices on the system.
You can enroll up to eight PC4164 wireless receivers. This will give
you a greater range in which to install wireless devices. It will also
allow you to install backup wireless receivers with overlapping
ranges, to provide increased security for the wireless zones on the
system.
NOTE: The maximum number of wireless zones you can enroll on the
system is 64, even if you install more than one PC4164 wireless
receiver.
ESCORT4580, PC4701 and PC4936 Enrollment
When enrolling the ESCORT4580, the PC4701 or the PC4936, the
keypad will display the message ’Looking for PC4XXX Module’.
The panel will automatically scan the Combus for the module.
Once it is found, the panel will confirm enrollment (e.g.
’ESCORT4580 Module Enrolled’). No tamper is required.
4.2 Deleting Modules
Ref # [0201] then scroll to desired module
Sometimes, a module must be deleted from the system. This
could be when zone expanders are enrolled out of sequence or if a
module is defective.
To delete a module, enter the following at any enrolled keypad:
1. Enter installers programming by pressing [*] [8] [Installer’s
Code].
2. Enter reference number [0201] then press [*].
3. Scroll through the different modules until the module you
wish to enroll is displayed. Press [*] to select.
4. Scroll to the correct module type, then to the correct module
number. For example, to delete LCD45XX Module 04, scroll
to ’LCD45XX (04)’. Press the [*] key to delete the module.
NOTE: When deleting and/or replacing zone expanders, all remain-
ing zone expanders should be re-enrolled. This will ensure proper
zone assignment and operation.
4.3 Confirming Modules
Ref # [0202] then scroll to desired module
In case module numbers were not recorded, you can verify this
information through the ’Confirm Module’ menu in the ’Module
Hardware’ programming section in installers programming.
This works just like enrolling modules. You will be prompted to
’Press Any Key On Desired Unit’ in the case of keypads and ’Create
Tamper on Desired Unit’ in the case of modules. Once the correct
action is taken, the keypad will display the module number (e.g.
LCD45XX Mod 02).

Table of Contents