22
pressed, the user may need to enter a valid access code if the
Cmd.Out X Rq Cd option is enabled for the command output.
Silence Trouble (21)*
Pressing this key silences trouble beeps for the partition. If the
Trouble Requires Code system toggle option is enabled, the user
will be required to enter an access code in order for this function
key to work (see
7.9 ”Access Code Options’).
Silence Bells (22)*
Pressing this key followed by entry of a valid access code will
silence the partition’s fire alarms.
Fire Reset (23)*
Pressing this key followed by entry of a valid access code will
restore all fire alarms.
Fire Drill (24)
Pressing this key followed by entry of a valid access or Master
code will initiate the Fire Drill. This is the equivalent of entering
[
?][6][Access/Master Code][5].
Lamp Test (25)
Pressing this key followed by entry of a valid access or Master
code will initiate the Lamp Test. This is the equivalent of entering
[
?][6][Access/Master Code][8] (see Instruction Manual, section
5.3 ’Lamp Test’).
Fire Insp Tst (26)
Pressing this key followed by the Walk Test Code will initiate the
Fire Inspector’s Test Mode. This is the equivalent of entering
[
?][6][Walk Test Code][4]. If the test mode is already active,
pressing this key followed by the Walk Test Code will disable the
test ([
?][6][Walk Test Code][5]).
User Help (27)
Pressing this key will automatically create a connection between
the keypad and the Escort4580. The Escort starts prompting
immediately through the Audio Station assigned to the keypad.
The Escort4580 v1.3 must be enrolled and programmed for this to
work. Make sure that this function key is not programmed to
require an access code entry (see
”Function Key Options’).
The intercom station must be programmed as ‘intercom’.
Quick Bypass (28)
Pressing this key, followed by entry of an access code, will bypass
all zones on the partition programmed as Quick Bypass for the
length of the Quick Bypass Duration. Press this function key
again during the Quick Bypass Pre-alert to restart the countdown.
This is the same as entering [?][6][Access/Master code][14]. See
”24Hr Quick Bypass (24)’.
Music Input (29)
Pressing this key will turn on the background music (if pro-
grammed) on all the audio stations which hear general pages.
NOTE: The Monitor and Music Input cannot be on at the same time.
If they are both enabled, the Monitor will take priority and the Music
will not be heard.
Temporary Code (30)
Pressing this function key, followed by an access code, will
enable/disable temporary codes on the partition assigned to the
keypad. The keypad will sound 3 short beeps when temporary
codes are enabled on the partition and one long beep when tempo
-
rary codes are disabled on the partition. The ’T-code’ LED on the
LCD45XX will be on when temporary codes are active, and off
when they are not active. See section
7.3 ”Programming Access
Codes’.
Cancel Key (31)
Pressing this key when the partition is NOT in alarm will:
Silence troubles (if in normal mode)
Exit from the current menu
When a user presses this key when the partition is in alarm the
panel will:
1. Request a valid access code.
2. Transmit a Cancel code to the central station.
3. Sound 3 beeps on the keypad, display "Alarm Canceled"
on the keypad and sound a voice message stating "Alarm
Canceled".
NOTE: For this feature to work, make sure that the Alarm Cancel
reporting code is programmed (see
Appendix B: ”Reporting Codes’).
NOTE: Alarm Cancel does not initiate listen-in.
Zone Control (32)
Pressing this key will cause the programmed zone to be violated.
One of zones 121-128 can be assigned to any function key. Do not
assign more than one function key to the same zone. Do not use
zones assigned to zone control keys for any other purpose.
The panel will follow the same procedure as when the zone is nor-
mally violated. The zone will then automatically restore. Zones
assigned to zone control keys will not be supervised.
NOTE: Do not assign fire zones (zone types 07-11) to this function
key.
Arm All (33)
Attempts to arm all partitions assigned to a specific user in Away
mode. If the function key is programmed to not require a code,
then the panel will attempt to arm all active partitions. If a parti
-
tion is not ready to arm, the message ’Unable to arm all partitions’
will appear and none of the partitions will be armed. This function
key option is only available to system keypads. If code is required
then the panel attempts to arm all partitions to which the code is
assigned.