Section 16: Diagnostics and Troubleshooting 46
16.1 General Diagnostics ................................................................... 46
16.2 Restoring Factory Default Programming ................................... 46
16.3 Hardware Reset .......................................................................... 46
16.4 Viewing Trouble Conditions ......................................................46
16.5 System Fault Squawk ................................................................. 47
Section 17: Local, Central & Remote Station Fire Installation
Instructions 49
17.1 Introduction ................................................................................ 49
17.2 Hardware Description and Specifications .................................. 49
Section 18: Fire Zone Types 51
18.1 Partitions and Fire System Configuration .................................. 51
18.2 Standard Fire Zone ..................................................................... 51
18.3 Delayed Fire Zone ...................................................................... 51
18.4 Auto Verify Fire ......................................................................... 52
18.5 Waterflow Zone .......................................................................... 52
18.6 Fire Supervisory Zone ................................................................ 53
18.7 PC4701 Zones ............................................................................53
18.8 4-Wire Smoke Detector Zones ................................................... 53
18.9 AMS-220 Addressable Smoke Detector Zones ......................... 53
18.10AMP-702 Addressable Fire Point Module .................................53
Section 19: PC4702BP Output Programming 54
19.1 Alarm Notification Output Types .............................................. 54
19.2 Programming PC4702BP Outputs ............................................. 54
19.3 Fire Bell Options ........................................................................ 54
19.4 Partitions and Fire System Configuration .................................. 54
Section 20: Fire System Operation 56
20.1 Manual Signal Silence ................................................................56
20.2 Automatic Signal Silence (Bell Cut-Off) ...................................56
20.3 Signal Silence Inhibit Timer (Fire Silence Delay) .....................56
20.4 Fire System Reset .......................................................................56
20.5 Manual Sensor Reset ([*][7][2]) .................................................56
20.6 Subsequent Alarm Operation ......................................................56
20.7 Fire Silence/Reset User Codes ...................................................57
20.8 Auto-Scroll LCD Keypad Display .............................................57
20.9 Fire Trouble Conditions ..............................................................57
20.10AC Delays ...................................................................................58
20.11Bypassing Fire Zones .................................................................58
20.12Fire Drill Feature ........................................................................58
20.13Fire Inspector Test ......................................................................58
20.14Testing AMS-220/220T Smoke Detectors .................................59
20.15Lamp Test ...................................................................................59
20.16PC4701 Remote Station Alarm/Trouble Relays .........................59
20.17Fire Reporting Codes ..................................................................59
20.18Upload/Download Considerations ..............................................60
Section 21: Listing Requirements 61
21.1 UL Listed Commercial Burglary and Residential Burglary
Installations .................................................................................61
21.2 Commercial Fire Alarm Installations .........................................61
21.3 ULC Listing Requirements ........................................................62
Appendix A: Wiring Diagrams 63
Appendix B: Reporting Codes 69
Appendix C: Zone Reporting Codes 72
ASCII Characters 73
This equipment, Alarm Controller PC4020 shall be installed and used within an
environment that provides the pollution degree max 2 and overvoltages category
II non-hazardous locations, indoor only. The equipment is fixed and perma-
nently connected and is designed to be installed by service persons only; [ser-
vice person is defined as a person having the appropriate technical training and
experience necessary to be aware of hazards to which that person may be ex-
posed in performing a task and of measures to minimize the risks to that person
or other persons. The equipment enclosure must be secured to the building struc-
ture before operation.
Internal wiring must be routed in a manner that prevents:
- Excessive strain on wire and on terminal connections;
- Loosening of terminal; connections;
- Damage of conductor insulation
Before servicing, disconnect the power (AC and DC) and telephone connection.
WARNING: Incorrect connection of batteries may result in battery rup-
ture or fire hazard. Do not allow metal objects to connect the positive and
negative terminals.
Ensure the batteries are connected with correct polarity [Red to (+), Black to (-)].
Failure to comply with this may result in battery rupture and/or Fire Hazard.
The battery is not power limited source.
WARNING: THIS PRODUCT USES LITHIUM BATTERIES. IMPROP-
ER HANDLING OF LITHIUM BATTERIES MAY RESULT IN HEAT
GENERATION, EXPLOSION OF FIRE, WHICH MAY LEAD TO PER-
SONAL INJURIES. THERE IS A DANGER OF EXPLOSION IF THE
BATTERIES ARE INSTALLED INCORRECTLY.
KEEP AWAY FROM SMALL CHILDREN, IF SWALLOWED
PROMPTLY SEE A DOCTOR.
Replace only with the same or equivalent type recommended by the manufactur-
er. Do not try to recharge these batteries.
Dispose of used batteries must be made in accordance with the waste recovery
and recycling regulations in your area.