50
• One – Power transformer – 16 VAC, 40 VA
PS4350 – External Battery Charger
• PC4055C beige cabinet - 15.0” x 15.0” x 6.9”
• PS4085 multi-rate charger module
• PT1012 transformer, 12 VAC, 160 VA
• Space for 60Ah, 12 volt sealed lead-acid battery
PC4612 – Fire Zone Annunciator (12 Zones)
Surface-mount LCD style plastic housing for Fire Zone Annunci-
ation includes:
• 10 Fire Alarm zone (Red indicators)
• Two – Fire Supervisory zone (Yellow indicators)
• One – common Bell zone Trouble (Yellow indicator)
• One – common Fire zone Trouble (Yellow indicator)
• One – common System Trouble (Yellow indicator)
• One – AC ON (green indicator)
• One – set user zone ID peel & stick labels
PC4632 – Point/Graphic Annunciator (32 Zones)
One – PC4032C surface mount beige cabinet 10.3” x 13.3” x 2.6”
includes:
• Continuous hinged, screw closure front panel
• One – PC4216, 16 zone Low-Power Output module – 12
V
DC, 50 mA per output
• One – PC4600LG, Pkg. Of four LED grids, covers entire dis-
play area
• One – PC4600LA-M, Pkg. Of 10 red, five yellow and one
green LED assemblies
• One – PC4632GP, Point/Graphic Display package
• Capacity – for two PC4216 output modules (for 32 zones)
PC4632FT – Flush Trim For PC4632
Provides 0.75” (2cm) matching trim all round the PC4632 annun-
ciator
PC4664 – Point/Graphic Annunciator (64 Zones)
One – PC4064C surface mount beige cabinet 18.7” x 13.3” x 2.6”
includes:
• Continuous hinged, screw closure front panel
• Two – PC4216, 16 zone Low-Power Output module – 12
V
DC, 50 mA per output
• Two – PC4600LG, Pkg. of 4 LED grids, covers entire display
area
• One – PC4600LA-M, Pkg. of 10 red, five yellow and one
green LED assemblies
• One – PC4600LA, Pkg. of 16 red LED assemblies
• One – PC4664GP, Point/Graphic Display package.
• Capacity – for four PC4216 output modules (for 64 zones)
PC4664FT – Flush Trim For PC4664
Provides 0.75” (2cm) matching trim all round the PC4664 annun-
ciator
Other System Modules
The following modules may be added to the basic system to
expand the zone capacity and add other functions.
• PC4108A – 8 zone expansion module
• PC4116 – 16 zone expansion module
• PC4164-RS* – 64 zone wireless receiver
• PC4216 – 16 zone low-power output module
• PC4204/PC4204CX – Power supply and quad relay module
(non-fire)
• LCD4500 – LCD Keypad (non-fire)
• LCD4501 – LCD keypad with five function keys (non-fire)
• PC4400 ** – Printer interface and DVAC module
• PC4820 – Dual card reader access control module
• LINKS1000* – Cellular communicator panel
• LINKS2150 – Long-range transmitter
• LINKS2150/2450 – Long-Range Radio communicator
* Residential use only.
** Burglary only.
Compatible Smoke Detectors
The following list of 2-wire smoke detectors have been listed as
compatible with the PC4701 Fire module two-wire smoke detec
-
tion zone:
• DSC – MN-220 – Photoelectric smoke detector
• DSC – MN-220T – Photoelectric smoke detector with 135°F
fixed heat detector
• Sentrol – ESL429AT
The following list of 4-wire smoke detectors are recommended
for use with the PC4020CF control panel:
• DSC – MN-240 Photoelectric smoke detector
• DSC – MN-240T Photoelectric smoke detector with 135°F
fixed heat detector
Alarm Notification Appliances
The following Audible and Visual Alarm Notification Appliances
are recommended for use with the PC4702BP Alarm Notification
panel:
• Wheelock models:
MT-12/24-R DSM-12/24-R
SM12/24-R RSS241575W-FR (15/75c)
RSS2415-FR (15c) RSS24110W-FR (110c)
RSS2475W-FR (75c) AS241575W-FR (15/75c)
AS2415W-FR (15c) AS24110W-FR (110c)
AS2475W-FR (75c)
• System Sensor models:
SS241575ADAS (15/75c) SS2415ADAS (15c)
SS251575ADA (15/75c) SS2415ADA (15c)
SS24110ADA (110c) SS2475ADA (75c)
MASS241575ADAS (15/75c) MASS2415ADAS (15c)