45
Specification
Circuit test
Test Voltage: 12 V p - p, 50Hz square wave. (Typical)
Max current: 100 mA (typical)
Indications: Open circuit, OK, Short circuit.
Insulation test
Range: 0 - 50 M
Accuracy: 5.0% ± 100 k
Compliance: 500 V at 0.5 M
Pass Band options: 0.25M, 0.3M, 0.5M, 1M, 2M, 4M, 5M, 7M, 8M, 10M, 20M, 50M
Earth Bond Test
Range: 0 - 999 m Resolution 1 m
1000 – 1999m Resolution 10 m
Accuracy: 0 <R> 499 m 5.0% ±5m
500 m <R> 1999 m 5.0% ±50m
Test Voltage: 10 V a.c. (Typical)
Test Current: 10A or 25A into 0.1 (typical)
Pass Bands: 50 m, 100 m, 200 m, 300 m, 400m, 500m, 600m, 750m, 800m, 1,
1.5, 2
Earth Continuity Test
Range: 0 - 999 m Resolution 1 m
1.00 - 9.99 Resolution 10 m
Accuracy: 5.0% ±10m
Test Voltage: 4 V d.c. (Typical)
Test Current: 200 mA short circuit (typical)
Pass Bands: 50 m, 100 m, 200 m, 500 m, 750m, 1, 1.5, 2, 2.5, 5, 7.5, 10
Operation Test
Range: 0 - 3.0 kVA.
Accuracy: 0 <VA> 99 VA: 5.0% ± 5 VA
100 <VA> 999 VA: 5.0% ± 10 VA
1.0 <VA> 3.0kVA: 5.0% ± 100 VA
Reference: Reading corrected to 230 V
Pass Band options: 50 VA, 100 VA, 200 VA, 350 VA, 500 VA, 700 VA, 1000 VA, 1200 VA, 1500VA,
2000 VA, 2500 VA, 3000 VA.