47
Specification
Environmental Specifications
Designed for indoor use or protected outdoor use.
Operational Temp Range: 0° - 40° C at 90% Relative Humidity
Storage Temp Range: -20° C to 60°C
Temperature co-efficient: 0.2% per °C (Ref temp. 20°C)
General features
Hard copy of results formatted as a pass / fail list.
On board real time clock module.
On board AVO Xpress software compatible asset database.
On board storage for 1000 test results (max).
Alphanumeric key pad.
Auto / Manual modes.
Two line LCD text display.
Communication Connectors
9 way male ‘D’ RS232:Interface to PC / bar code scanner
8 bits, no parity, 1 stop bit.
PC: 9600 baud
Scanner: 2400 baud.
25 way female ‘D’: Parallel printer for results.
Cleaning
Disconnect instrument from mains supply. Wipe with a clean cloth dampened with soapy water or Isopropyl Alcohol (IPA).
Mechanical Specifications.
Weight: 6 kg (DV)
6.95 kg (DVF)
Dimensions: Width - 375 mm (inc handle and lid)
Depth - 330 mm (inc hinges)
Height - 200 mm (approx).