QUICK START MANUAL Document reference MAVM600MK2MPS-QS/E
VM600
Mk2
machinery protection system (MPS) Edition 2 - February 2021
3-6
Common VibroSight System Manager tasks
OVERVIEW OF VM600
Mk2
MACHINERY PROTECTION SYSTEM (MPS) SOFTWARE
The main window (centre) updates to display system information for the MPC4
Mk2
module, grouped in sections such as General information, Time synchronisation,
Network, Diagnostics and Firmware versions.
3.3.3.1 Notes on displaying information about a MPC4
Mk2
module
If the main window (centre) does not display much information for the MPC4
Mk2
module and,
for example, mostly displays Not available, then check the value displayed for Firmware
compatibility with VibroSight, under General information.
If Firmware compatibility with VibroSight: Too old is displayed, then it is probably necessary
to either change the MPC4
Mk2
module to a later version of firmware (or change the VibroSight
software to an earlier version) in order to display information about the MPC4
Mk2
module.
3.3.4 Checking the operating mode for a MPC4
Mk2
module
VibroSight System Manager is used to display the operating mode for a MPC4
Mk2
module.
The operating mode for a MPC4
Mk2
module is part of the general information displayed about
a MPC4
Mk2
module.
Follow the procedure in 3.3.3 Displaying information about a MPC4
Mk2
module and when the
main window (centre) updates to display system information for the MPC4
Mk2
module, check
the value displayed for Operating mode, under Firmware versions.
For the MPC4
Mk2
module, there are four operating modes: Power-up, Operational, Fail-safe
and Recovery.
See 4.2 MPC4
Mk2
module operating modes for further information.
3.3.5 Checking the firmware for a MPC4
Mk2
module
VibroSight System Manager is used to display information about the firmware on a MPC4
Mk2
module.
information about the firmware on a MPC4
Mk2
module is part of the general information
displayed about a MPC4
Mk2
module.
Follow the procedure in 3.3.3 Displaying information about a MPC4
Mk2
module and when the
main window (centre) updates to display system information for the MPC4
Mk2
module, check
the firmware information displayed under General information.
If a particular firmware has been uploaded to and is available for use by the MPC4
Mk2
module, then the PNR for the firmware is listed by System Manager, under
General information. For example, 640-025-003-000 for the operational firmware.
If a particular firmware has not been uploaded to and is available for use by the MPC4
Mk2
module, then the PNR for the firmware is not listed (that is, left blank).
See 4.1 MPC4
Mk2
module firmware for further information.

Table of Contents

Other manuals for Meggitt vibro-meter VM600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Meggitt vibro-meter VM600 and is the answer not in the manual?

Meggitt vibro-meter VM600 Specifications

General IconGeneral
BrandMeggitt
Modelvibro-meter VM600
CategoryProtection Device
LanguageEnglish