19: Percentage of bus card
Only the following function No. will
be shown in shortcut menu: 0~8
P09.30
Maximum
output pulse
frequency
Maximum
output pulse
0.1~50.0 (Maximum 50.0k) 0.1kHz 10.0
P09.31
Pulse output
central point
selection
Pulse output
central point
0: Without central point
1: With central point
It is (P09.30)/2. It is positive when
the frequency is less than the
central point frequency
2: With central point
It is (P09.30)/2. It is positive when
the frequency is larger than the
central point frequency
1 0 ×
P09.32
Pulse output
filtering time
Pulse output
filtering time
0.00~10.00s 0.01s 0.05 ×
P09.33
Flux
detection
value
Flux
detection
value
10.0~100.0%
0.1% 100.0% ×
P09.34
Zero-speed
threshold
Zero-speed
threshold
0.0~100.0% of maximum
frequency
1.0%
1.0
×
Group P10: Analog input/output terminal parameters
P10.00
Analog input
properties
Analog input
properties
Unit place: AI1
0: Voltage input
1: Current input
Tens place: AI2
0: Voltage input
1: Current input
AI3 is the differential voltage input
1 00 ×
P10.01
Analog AI
function
selection
AI function
selection
Unit place of LED: AI1 function
selection
0: No function
1: Main reference frequency
setting
2: Auxiliary reference frequency
setting
3: Torque offset
4: Speed limit value 1
5: Speed limit value 2
6: Torque limit value 1
7: Torque limit value 2
8: Torque command (reference)
9: Main reference frequency
setting (unipolar)
A: Auxiliary reference frequency
1 000 ×