Glossary
aqua dem
demineralized water
aqua dest
distilled water
Authorized persons
Medical specialist dealers, technician from depots or with
customer service designated by MELAG, who were trained
by MELAG
Batch
Collection of the items to be sterilized that together
passed through one and the same sterilization program
BGV A1
Specifications from professional associations
(Berufsgenossenschaftliche Vorschriften) the principles
of prevention
CF card
Compact Flash card;
A memory card for digital data in compact form;
CF is a standardized term, i. e. these memory cards can
be used in every device with a CF slot. The CF card can
be read and possibly written by every device that supports
the standard.
Condensate
A liquid (e.g. water), which forms upon cooling from the
vaporous state and thereby separates
Conductivity
is the opposite of electrical resistance; measured in micro-
Siemens / centimetre (µS/cm); the greater the amount of
dissolute matter in the water, the better it can conduct
electrical current and thus the higher its conductivity.
distilled water ideally has the conductivity zero
Conductivity measurement
Measurement of the Conductivity
Corrosion
Chemical change or destruction of metallic materials by
water and chemicals
Delayed boiling
This is the phenomenon that in certain conditions liquids
can be heated beyond their boiling point without boiling;
this state is unstabile; a slight shock can cause a very
rapid formation of large gas bubble which expands like an
explosion
Demineralised water
Also designated as aqua dem; water to a large extent
without the minerals which occur in normal mineral or tap
water; is obtained by ion exchange from normal tap water.
It is employed here as feed water
DGSV
Deutsche Gesellschaft für Sterilgutversorgung (German
Association for the Sterilized Equipment Ordinance). The
DGSV training centres are specified in DIN 58946, part 6
as "Requirements of personnel".
DIN 58953
Norm Sterilization, sterile goods supply
DIN EN 867-5
European standard: non-biological systems for use in
sterilizers Part 5: Stipulations of indicator systems and
testing bodies for performance tests of small sterilizers of
Type B and Type S
DIN EN 868-8
European standard: Packing materials and sytems for
medical devices to be sterilized
DIN EN ISO 11140-1
European standard Sterilization of products for health
care chemical indicators Part 1: General requirements
DIN EN ISO 11607-1
Standard Requirements on materials, sterile barrier
systems and packaging systems; this standard is a
harmonization of the DIN EN 868 Part 1 and the
international standard DIN EN ISO 11607.
DIN EN 13060
European standard Small steam sterilizers
DIN EN 285
European standard sterilization steam sterilizers
large sterilizers
Display
Display panel on electronic devices for communicating
information. Here: Graphic display of the control panel
Distilled water
From lat. aqua destillata; also designated as aqua dest;
water, which is largely freely of salts, organic materials and
microorganisms, is obtained by distillation (evaporation
and subsequent condensation) from normal tap water or
pre-cleaned water. It is employed here as feed water
Dynamic pressure test of the sterilization chamber
Serves to verify that the rate of the change of pressure
occurring in the sterilization chamber during a sterilization
cycle does not exceed a certain value, which could lead to
damage of the wrapping material
[DIN EN 13060]
Empty chamber test
Test without load; carried out in order to evaluate the
performance of the sterilizer without the influence of the
load; permits checking the maintained temperatures and
pressures with respect to the intended settings
[DIN EN 13060]
Evacuation
Creation of a vacuum in a chamber
Feed water
is required for the creation of water steam for the
sterilization; typical values for the water quality according
to DIN EN 285 or DIN EN 13060 Appendix C
Flow-drying
Drying, which removes moisture in the chamber using a
mechanically generated air flow, is usually supported by
heat
Fractionated flow method
Overpressure method in which the air is expelled from the
chamber and the items to be sterilized by alternating
between steam entry and steam outlet.
FTP
(File Transfer Protocol) is a data transmission procedure
serving to transport data from the internet. These data can
contain programs, files or information. Special FTP
programs (FTP clients) serve for uploading any data on a
server.
Heating-up period
After switching on the steam sterilizer or after starting a
sterilization program., it ist he time required for heating-up