Dropping speed reached at the end of dosing starting from the value set for the
Dropping speed
Duration of the final dropping phase carried out with steady belt and/or nozzles
(according to the type of product selected) to even dosing ending
Intake time at the end of the tray
First row dropping time
correction
Added to or deducted from the dosing time (or the initial uniformity) of the first row of
each tray
Allows the selection of the dosing unit to be used between Rollers and Pump
Thickness of product layer
With Sponges, backward movement made at the start of the tray, with dosing active,
to even dosing at the start of the tray.
Space between the tray edge and the initial dropping position of the first row
Duration of the initial dropping phase carried out with steady belt and/or nozzles
(according to the type of product selected) to even dosing start
Table lowering speed during depositing or during positioning between layers
Duration of the nozzle rotation phase, during which the product is also dosed
Number of rows created on each tray
Time elapsed between the end of the dosing phase and the beginning of the vacuum
phase.
Total height of the chosen product
Length of the product to be made
Extra nozzle rotation at the end of dropping to prevent the formation of a peak
Rotation on Final uniformity
- ON: nozzle rotation active during the Final uniformity
- OFF: nozzle rotation not active during the Final uniformity
Rotation on Initial uniformity
- ON: nozzle rotation active during the Initial uniformity
- OFF: nozzle rotation not active during the Initial uniformity
- ON: nozzle rotation is active during depositing of the indicated layer
- OFF: nozzle rotation is inactive during depositing of the indicated layer
- ON: nozzle rotation active during the forward phase
- OFF: nozzle rotation not active during the forward phase
- ON: nozzle rotation is active during depositing with conveyor lowering
- OFF: nozzle rotation is inactive during depositing with conveyor lowering
Belt forward/backward movement at the end of dropping to prevent the formation of a
peak
Distance between one row and the next one
- Top stop: table stopped at the high position during the dosing cycle
- Up/Down: table with vertical up and down movements for each row
- Low stop: table stopped at the low position during the dosing cycle
Tray presence memorization
- ON: the tray sensor is disabled after the tray has been detected
- OFF: the tray sensor is continually active
Intake time at the end of dosing
Wire cutting system speed (optional)
Time elapsed between wire cutting system starting and the belt conveyor forward
command