USE AND MAINTENANCE MANUAL
8.2. STATIONARY MOULD DISASSEMBLING AND CLEANING
Wash the die thoroughly after every work change proceeding as follows:
1. Loosen the gib stop nuts and slip the mould out.
2. Unscrew all nozzles from the mould using the supplied tool
3. Clean the nozzles in all their parts.
4. Clean the mould in all its parts.
5. Dry and wait for the die and nozzles to cool down.
8.3. ROTARY MOULD DISASSEMBLING AND CLEANING
Wash the rotary mould thoroughly before starting any new process following the following steps:
1. Loosen the gib nuts and slip the mould out
2. Unscrew all nozzles from the die using the supplied tool
3. After unscrewing the blocking nuts, remove the upper plate
4. Remove the spacers
5. Remove the gears
6. Clean the nozzles thoroughly
7. Clean each one of the mould components
8. Dry and wait for all parts to cool down