Chapter 2 Basic Operation
2-12
Perform test printing with the test
pattern for checking white ink
It makes easier to check if print the background to the
white ink locations in the pattern.
1
Press the
(TEST PRINT/CLEANING)
,
and press the key in LOCAL.
TEST PRINT MENU will be displayed.
2
Press to select “SpotColor
Check”.
3
Press the key.
Print a test pattern in the following orders.
(1) Print the pattern daubed with black.
(2) Dry the pattern for thirty seconds.
When press the [ENTER] key, cancel waiting
time and shift to step (3).
(3) Return the media automatically and print the
test pattern.
4
Check the printed test pattern.
When the result is normal, end the operation.
When the result is abnormal, perform head
cleaning. P.2-12
Head Cleaning
About head cleaning
Check the printed test pattern result and perform cleaning
depending on the status.
Select one from the four types below:
NORMAL : When any line is missing
SOFT : When only head wiping is needed (when
lines are bent)
HARD : When poor image quality cannot be
improved even by NORMAL or SOFT
cleaning
ULTRA : When poor image quality cannot be
improved even by HARD cleaning
Perform head cleaning depending on
the test printing result
There are four types of head cleaning. Use one by
checking the test pattern.
1
Press the
(TEST PRINT/CLEANING)
key in LOCAL.
CLEANING MENU will be displayed.
2
Press to select the cleaning
type.
NORMAL : Select this if any line is missing.
SOFT : When only head wiping is desirable.
(in case of bent lines)
HARD : Select this if inferior printing cannot
be improved even by [NORMAL] or
[SOFT] cleaning.
ULTRA : Select this if inferior printing cannot
be improved even by [HARD]
cleaning.
3
Press the key.
4
Perform test printing again, and check the
result.
Repeat the cleaning and the test printing until the
printing result becomes in normal.
Abnormal pattern
Clogged with ink
Normal pattern
Nozzles are dirty
When the image quality is not improved after the
head cleaning.
Clean the wiper and ink cap. ( P.4-6)
Wash the head nozzle. ( P.4-7)