3-12
Chapter 3 Mchine setting
Setting a AUTO Power-off
When no operation has been performed for the set time,
the power supply is automatically turned “OFF”.
1
Press the
(MENU)
(twice)
key in LOCAL.
MACHINE SETUP MENU will be displayed.
2
Press to select “AUTO POWER
OFF”, and press the key.
3
Press to select a set value, and
press the key.
Set Value : none, 10 to 600min
4
Press the key several times
to end the setting.
Setting Take-up unit
Set the operation method when press the ON / OFF
button on the take-up unit.
Also, when the optional tension bar is installed, for setting
whether the tension bar is used or not used.
1
Press the
(MENU)
(twice)
key in LOCAL.
MACHINE SETUP MENU will be displayed.
2
Press to select “TAKE-UP
UNIT”, and press the key.
3
Press the key.
“TAKE-UP UNIT” will be selected.
4
Press to select a set value, and
press the key.
Set Value : ON/ OFF
5
Press , and press the key.
“TENSION BAR” will be selected.
6
Press to select a set value, and
press the key.
Set Value : ON/ OFF
7
Press , and press the key.
“TAKE-UP SW” will be selected.
8
Press to select a set value, and
press the key.
Set Value : Continuance/ Temporary
Continuance :
Switching ON / OFF the winding operation when
pressing the switch each time. (Take-up unit in
operation does not stop until press again ON /
OFF switch.)
Temporary :
Do the winding operation only while holding
down the switch. (When release the switch,
winding operation is stopped. )
9
Press the key several times
to end the setting.
EVENT MAIL
Server Setup
(P.3-17)
SMTP Address Set the SMTP server.
SMTP Port No. Set the SMTP port number.
SENDER ADDRESS
Set the e-mail address to be used as the sender mail
address.
Authentication
POP before
SMTP
Set the SMTP server authentication method (SMTP
authentication).
SMTP
Authentication
OFF
User Name
*2
Set the user name used for the authentication.
Pass Word *2 Set the password used for the authentication.
POP3 Address
*3
Set the POP server.
APOP *3 Set ON/ OFF of APOP.
Transmit Test
(P.3-18)
Send the test e-mail.
RESET
( P.3-19)
All setting values are returned to the status
default.
*1. Settable when both of DHCP and AutoIP are [OFF]
*2. Settable only when Auth. is not OFF
*3. Settable only when Auth. is POP before SMTP
Function name Set value Default Meaning
If the machine received data from the PC in the
auto-power-off status, the power supply is turned
ON, however, printing operation is not started
automatically.