D F07 Setting data width of zero tracking
Initial value00000 00000Zero tracking OFF
Setting range 00000 to 00099
Unit 0.5D
Data width of 49.5D with the setting of “00099”.
Effective only when the value from 00001 to 00099 is set with the F08.
D F08 Setting zero tracking time width
Initial value00020 00000Zero tracking OFF
Setting range 0000000099
Unit 0.1 s
Time width of 9.9 s with the setting “00099”.
Effective only when the value of 0000100099 is set with the F07.
D F09 Setting digital filter for stabilized filter
Initial value00001 00000Stabilized filter OFF
Setting range 0000000002
Average of 2
(m7)
times
Selects average times of digital filter for stabilized filter.
When the figure grows larger, the filter will be stronger, then the effects
from vibration and so on are scarcely shown on the display.
Effective only when setting is made with the value from 00001 to 00099 with
F10, and the value from 00001 to 00999 is set with the F97.
D F10 Setting time width for stabilized filter
Initial value00020 00000Stabilized filter OFF
Setting rage0000000999
Unit0.01 s
Time width of 9.99 s with the setting of “00999”.
Effective only when the value from 00001 to 00007 with F09 and the value
from 00001 to 00999 with F97 are set.
D F20 Selection of target of BCD output
Initial value00002 00000Display
00001Net weight
00002Gross weight
00003External selection
When “Display” is selected, BCD output interlocks with the display.
And when “Net weight” is selected, B CD output will interlock with the value
of “Net weight” at the time of executed tare weight cancellation and also
BCD output interlocks with “Gross weight” individually at the time of Tare
weight cancellation clear.
When “Gross weight” is selected, BCD output will interlock with the value
of “Gross weight”, whichever Tare cancellation is executed or not.
When “External selection” is selected, the target of BCD output can be
chosen among “Display”, “Net weight” and “Gross weight” through the
input of SEL1 or SEL2 at external control input.