8−2. Function on Function data
D F−01 Selection of decimal point display position
Initial value=00000 00000=Non
00001=10
1
00002=10
2
00003=10
3
00004=10
4
D F−02 Selection of target for display
Initial value=00000 00000=Net weight (Interlocked with A/Z.)
00001=Net weight (Interlocked with A/Z.)
00002=Gross weight
※When “Net weight” is selected and Tare weight cancellation is executed as
well, the load display will become “Net weight” and in the next, when Tare
weight cancellation is cleared, the load display shows “Gross weight”.
※When “Gross weight” is selected, load display always shows fixed “Gross
weight”, whichever Tare weight cancellation is executed or not.
D F−03 Selection of display rate
Initial value=00000 00000=4 times/s
00001=20 times/s
00002=50 times/s
D F−04 Setting digital filter
Initial value=00033 Setting range:=00000〜00077
Average of 2
(m+1)
×2
(n+1)
times
※Select the average times for digital filter. When the figure grows larger, the
filter will become stronger, then effects from vibrations and so on are
scarcely shown on the display. Conversely, if too large figure is selected, the
response of variation of input sensor will become worse.
※Using the digital filter where vibrations and so on may exist is effective for
removing the deflection on the display.
D F−06 Setting key lock
Initial value=00000 10
0
digit:“CHECK” key
10
1
digit:“FUNC.” key
10
2
digit:“ZERO” key
10
3
digit:“A/Z OFF Y” key
10
4
digit:“A/Z A ” key
※Each “CHECK”, “FUNC.”,“ZERO”,“A/Z OFF Y” and “A/Z A” can be locked
individually. Key lock cancellation is made by setting “0”, and key lock is
made by setting “1”.
Moreover, when the “FUNC.” key is key locked , lock on “FUNC.” key will
be cancelled only once after the “FUNC.” key is pressed together with the
“ENTER” key for more than 3 s.