MIRCOM TECHNOLOGIES LIMITED, 9500 Series: No Subscriber Line Page 45
SET DOOR TIMER
To change Door-Open Timer (factory default is 10 seconds), Scroll through until you reach the feature as shown
below.
Adjust Door-Open
Timer - Press #
Press # to access the feature. The display should appear...
Door-Open Timer
00 to 99 Sec. _ _
Enter the desired door-open period. The next display should appear...
#=Store, *=Abort
00 to 99 Sec. x x
Press # to store or * to abort entry. The next display should appear...
Press *
To exit
Press * to exit to PROGRAM MODE menu. To quit, enter *000 wile at PROGRAM MODE menu to return to
NORMAL MODE.
ELEVATOR-RECALL (RESTRICTION) (9502A ONLY)
The system can provide elevator recall (restriction). Scroll down to the following feature.
[1=Bck] [3=Fwd]
Do you want to edit
Elevator-Recall ID?
[*=Abort] [#=Yes]
Press # to edit. The menu should appear ...
-Program Options-
Elevator-Relay
Card 1-8, 9-0 0
Please enter choice:
Enter one digit 1 to 8 for Elevator-Recall (Restriction) feature. Enter 0 or 9 for normal operation without Elevator-
Recall (Restriction). For more information see the Elevator-Recall (Restriction) section in this manual.
SET ON-LINE TIMER (9501A only)
To change the On-Line period, scroll through until you reached the feature as shown below.
Adjust On-Line
Timer - Press #
Press # to access the feature. The display should appear...
On-LINE Timer
00 To 99 Sec. _ _
Enter the On-Line period. The next display should appear...