4 Calibration assistance function
4-22 Automatic Calibration
(4-3) Set robot data
Set calibration data from the automatic calibration screen of RT ToolBox 3.
Launch the automatic calibration screen
Start RT ToolBox 3, select <Tool> - <Automatic Calibration>, Display the automatic calibration screen.
<Automatic Calibration> is not displayed when offline.
Set the initial data
The Auto Calibration screen is set as follows.
Calibration
Select the the calibration number.
Selection range
Calibration1 to Calibration8
Camera Position
Select camera setting method.Click the [Camera
Position] button to display the schematic diagram of the
setting method.
Selection:Fixed Method
Top Fixed
/ Fixed Method
Bottom Fixed
/ Hand-eye Method
Vision Maker
Select maker of vision sensor.
Selection:Only Cognex
COM Port
Select COM port number.
Selection range
COM2 to COM8
Tool No#
Select the tool parameter number. (*1)
Selection range
Tool1 to Tool16
Marker Tool [mm]
Set approximate value of marker tool length. (*2)
Fixed Method: Tool coordinates from the flange center
to the mark position.
Hand-eye Method: Tool coordinates from the center of
the flange to the camera center.