CHAPTER 13 COMMUNICATIONS USING A RANDOM ACCESS BUFFER
13
13.2 Communication Structure
13.2 Communication Structure
This section describes the structure of communications using a random access buffer.
(1) Data flow
The data flow in communications using a random access buffer is as follows. The FROM/TO instructions or
intelligent function module devices are used to access a random access buffer from a CPU module.
Communications can be performed only with connected devices where communications using a fixed buffer in the
"Procedure Exist" control method are set using the connection with Open completion signal of an E71 on.
Communications are performed asynchronously with the program. If synchronization is required, use communications
using a fixed buffer.
(2) Connected devices where data communications can be performed
Data communications can be performed with the following connected devices:
Devices in Ethernet where an E71 is connected
Devices connected using the router relay function
CPU module
Using the FROM/TO
instructions or an
intelligent function module device
Random
access
buffer
Connected
device
Read request
Reading data
Writing data
E71