CHAPTER 7 COMMUNICATION PROCEDURE
7
7.1 Setting Parameters Required for Communications
7.1.1 Parameter list
7.1 Setting Parameters Required for Communications
This section describes how to set parameters to communicate between the E71 and connected devices.
7.1.1 Parameter list
The following table lists parameters set through a programming tool.
Item Description Reference
Network
Parameter
Basic setting
Network Type
Configure settings to use the E71 as a network module. Page 66, Section 7.1.2
Start I/O No.
Network No.
Group No.
Station No.
Mode
Operation Setting
Configure the settings, such as an IP address, to
connect the E71 to Ethernet.
Page 67, Section 7.1.3
Initial Setting Set a data communication timer value. Page 311, Appendix 4.1
Open Setting Configure connection settings.
Page 69, Section 7.1.4,
Parameter setting of each
function
Router Relay Parameter
Configure settings to communicate with connected
devices on Ethernet via a router and a gateway.
MELSEC-Q/L Ethernet
Interface Module User's
Manual (Application)
Station No. <-> IP Information
Configure settings (e.g. network number and station
number) to communicate with other network modules.
FTP Parameters
Configure the settings of the file transfer (FTP)
function.
E-mail Setting
Configure the settings of the e-mail function and the
automatic notification function.
Interrupt Settings
Set the control number (SI) on the E71 side to request
an interrupt to the CPU module.
Page 131, Section 12.5.1
Routing Parameters
Set the communication path to communicate with a
station having a different network number.
MELSEC-Q/L Ethernet
Interface Module User's
Manual (Application)
Valid Module During Other Station
Access
Select a relay module when an access request with no
network number specified is issued from another
station.
-
Predefined Protocol Support Function
The connected device side protocol can be easily
selected, or created/edited from the Predefined
Protocol Library of GX Works2.
Page 95, CHAPTER 11
Remote Password Select the connection protected by a remote password. Page 181, Section 14.4