CHAPTER 8 CONNECTING MELSOFT PRODUCTS AND A GOT
8
8.2 Data Communication Procedure
8.2 Data Communication Procedure
This section describes the data communication procedure in the MELSOFT connection.
Ex.
Connecting the E71 and a personal computer (programming tool)
1. Write the parameter settings ( Page 69, Section
7.1.4) in the CPU module. To connect multiple
products in the TCP/IP communications, set the
connection for the second product or more in the
open setting. In the following cases, the open
setting is not required.
Only one product is connected in the TCP/IP
communications.
The network is running in the UDP/IP communications.
2. Set the connection target in the programming tool.
Connection destination window [Connection1]
3. Select "Ethernet Board" under "PC side I/F" and
double-click the item. The window shown to left
appears.
On the window, enter the network number and station
number of the personal computer, not of the E71.
Determine the network number and station number of
the personal computer as follows:
The network number must be the same as that of the
E71.
The station number must be different from that of the
E71 on the same network.