43
CHAPTER 3 SPECIFICATIONS
3
3.5 Buffer Memory
3.5.2 List of buffer memory addresses
512 and 513
(200
H
and 201
H
)
Router relay
parameter setting
area
Sub-net mask
0
H
514 and 515
(202
H
and 203
H
)
Default router IP address
0
H
516
(204
H
)
Number of registered routers
0
H
517 and 518
(205
H
and 206
H
)
Router 1
Sub-net address
0
H
519 and 520
(207
H
and 208
H
)
Router IP address
0
H
521 to 524
(209
H
to 20C
H
)
Router 2 (The bit configuration is the same as Router 1.)
525 to 528
(20D
H
to 210
H
)
Router 3 (The bit configuration is the same as Router 1.)
529 to 532
(211
H
to 214
H
)
Router 4 (The bit configuration is the same as Router 1.)
533 to 536
(215
H
to 218
H
)
Router 5 (The bit configuration is the same as Router 1.)
537 to 540
(219
H
to 21C
H
)
Router 6 (The bit configuration is the same as Router 1.)
541 to 544
(21D
H
to 220
H
)
Router 7 (The bit configuration is the same as Router 1.)
545 to 548
(221
H
to 224
H
)
Router 8 (The bit configuration is the same as Router 1.)
549
(225
H
)
System area
550 to 551
(226
H
and 227
H
)
Station No.<-> IP
information setting
area
System area
552
(228
H
)
Number of conversion table data
0
H
553 and 554
(229
H
to 22A
H
)
Conversion
information
No.1
Communication request destination/source stations
network number and station number
0
H
555 and 556
(22B
H
to 22C
H
)
External station Ethernet module IP address
0
H
557 and 558
(22D
H
to 22E
H
)
System area
559 to 564
(22F
H
to 234
H
)
Conversion information No.2 (The bit configuration is the same as Conversion information No.1.)
to to
931 to 936
(3A3
H
to 3A8
H
)
Conversion information No.64 (The bit configuration is the same as Conversion information No.1.)
937 and 938
(3A9
H
and 3AA
H
)
Subnet mask pattern for CC-Link IE Controller Network, CC-Link IE Field
Network, MELSECNET/H, and MELSECNET/10 routing
0
H
939 to 943
(3AB
H
to 3AF
H
)
System area
Address
Application Name Initial value
Programming
tool setting
applicability
Decimal
(Hexadecimal)