48
20765 to 20771
(511D
H
to 5123
H
)
HTTP status
storage area
Error log block 4 (The bit configuration is the same as Error log block 1.)
20772 to 20778
(5124
H
to 512A
H
)
Error log block 5 (The bit configuration is the same as Error log block 1.)
20779 to 20785
(512B
H
to 5131
H
)
Error log block 6 (The bit configuration is the same as Error log block 1.)
20786 to 20792
(5132
H
to 5138
H
)
Error log block 7 (The bit configuration is the same as Error log block 1.)
20793 to 20799
(5139
H
to 513F
H
)
Error log block 8 (The bit configuration is the same as Error log block 1.)
20800 to 20806
(5140
H
to 5146
H
)
Error log block 9 (The bit configuration is the same as Error log block 1.)
20807 to 20813
(5147
H
to 514D
H
)
Error log block 10 (The bit configuration is the same as Error log block 1.)
20814 to 20820
(514E
H
to 5154
H
)
Error log block 11 (The bit configuration is the same as Error log block 1.)
20821 to 20827
(5155
H
to 515B
H
)
Error log block 12 (The bit configuration is the same as Error log block 1.)
20828 to 20834
(515C
H
to 5162
H
)
Error log block 13 (The bit configuration is the same as Error log block 1.)
20835 to 20841
(5163
H
to 5169
H
)
Error log block 14 (The bit configuration is the same as Error log block 1.)
20842 to 20848
(516A
H
to 5170
H
)
Error log block 15 (The bit configuration is the same as Error log block 1.)
20849 to 20855
(5171
H
to 5177
H
)
Error log block 16 (The bit configuration is the same as Error log block 1.)
20856 to 20994
(5178
H
to 5202
H
)
System area 
20995
(5203
H
)
Disconnection
detection storage
area
Disconnection detection count
0
H
20996 to 21055
(5204
H
to 523F
H
)
System area 
21056
(5240
H
)
*1
Receive buffer
status storage area
Receive buffer full detection signal
0: Receive buffer not full
1: Receive buffer full
0
H
21057 to 21119
(5241
H
to 527F
H
)
System area 
21120
(5280
H
)
IP address status
storage area
Same IP address detection flag
0: Unique IP addresses
1: Same IP address for multiple stations
0
H
21121 to 21123
(5281
H
to 5283
H
)
The MAC address of the station that has been already connected to the
network (The address is stored in the station with the same IP address.)
FFFFFFFFFFFF
H
21124 to 21126
(5284
H
to 5286
H
)
The MAC address of the station with the IP address used for another
station (The address is stored in the station that has been already
connected to the network.)
FFFFFFFFFFFF
H
21127 to 21279
(5287
H
to 531F
H
)
System area 
Address
Application Name Initial value
Programming
tool setting
applicability
Decimal
(Hexadecimal)

Table of Contents