EasyManua.ls Logo

Mitsubishi Electric Q170MSCPU-S1 - Page 235

Mitsubishi Electric Q170MSCPU-S1
264 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
APP - 22
APPENDICES
2) SV22 (Q170MS_SV22_GX2) (Project for virtual mode switching method)
When using Q170MSCPU-S1, change the PLC type to "Q06UDH" in the
change PLC type of GX Works2.
a) I/O assignment
• I/O assignment
Setting items Description
Slot PLC PLC 1 2 3 4 5 6 7
Type PLC No.1 PLC No.2 Empty Empty Empty Empty Empty Empty Empty
Points 0 point 0 point 0 point 0 point 0 point 0 point 0 point
Start XY 3E00 3E10 0000 0000 0000 0000 0000 0000 0000
Switch
setting
Switch 1
Switch 2
Switch 3
Switch 4
Switch 5
Detailed
setting
Error time output mode
Hardware error time
PLC operation mode
I/O response time
Control PLC PLC No.1 PLC No.1 PLC No.1 PLC No.1 PLC No.1 PLC No.1 PLC No.1
• Base setting
Setting items Description
Slots (Main) 8
Base mode Detail
b) Multiple CPU setting
Setting items Description
1 No. of PLC 2 modules
2 Host CPU number No specification
3 Operating mode All station stop by stop error of PLC1/PLC2
4 Multiple CPU synchronous startup setting "PLC No.1", "PLC No.2" checked
5 Online module change "Enable online module change with another PLC" not checked
6 Input sharing when using Multiple CPUs "All CPUs can read all inputs" not checked
7 Output sharing when using Multiple CPUs "All CPUs can read all outputs" not checked
8
Multiple CPU high speed transmission
area setting
Use multiple CPU high speed communication
PLC
CPU specific send range
User setting area Auto refresh
point (k) I/O No. point Start End point
No.1 7 U3E0 6978 G10000 G16977 190
No.2 7 U3E1 5838 G10000 G15837 1330