2 SYSTEM CONFIGURATION
Motion controller related module (continued)
Part name
Model name
(Note-1)
Description
Current
consumption
5VDC[A]
Remark
Large capacity
battery holder
Q170MSBAT-SET Battery holder for Q7BAT (Attachment Q7BAT) ——
Internal I/F
connector set
LD77MHIOCON
Incremental synchronous encoder/Mark detection signal interface
connector (Not included with Q170MSCPU/Q170MSCPU-S1)
——
Power supply
module
(Note-4)
Q61P 100 to 240VAC input, 5VDC 6A output
——
Q62P 100 to 240VAC input, 5VDC 3A/24VDC 0.6A output
Q63P 24VDC input, 5VDC 6A output
Q64PN 100 to 240VAC input, 5VDC 8.5A output
Extension base
unit
(Note-5)
Q52B
Number of I/O modules installed 2 slots, type not requiring power supply
module
0.08
Q55B
Number of I/O modules installed 5 slots, type not requiring power supply
module
0.10
Q63B Number of I/O modules installed 3 slots 0.11
Q65B Number of I/O modules installed 5 slots 0.11
Q68B Number of I/O modules installed 8 slots 0.12
Q612B Number of I/O modules installed 12 slots 0.13
Extension cable
QC05B Length 0.45m(1.48ft.)
——
QC06B Length 0.6m(1.97ft.)
QC12B Length 1.2m(3.94ft.)
QC30B Length 3m(9.84ft.)
QC50B Length 5m(16.40ft.)
QC100B Length 10m(32.81ft.)
SSCNET
cable
MR-J3BUS
M
• Q170MSCPU
MR-J4(W)- B/MR-J4(W)- B MR-J4(W)- B/
MR-J4(W)-
B LJ72MS15
• Q170MSCPU
MR-J3(W)- B/MR-J3(W)- B MR-J3(W)- B
• Standard cord for inside panel
0.15m(0.49ft.), 0.3m(0.98ft.), 0.5m(1.64ft.), 1m(3,28ft.), 3m(9.84ft.)
——
MR-J3BUS M-A
• Q170MSCPU
MR-J4(W)- B/MR-J4(W)- B MR-J4(W)- B/
MR-J4(W)-
B LJ72MS15
• Q170MSCPU
MR-J3(W)- B/MR-J3(W)- B MR-J3(W)- B
• Standard cable for outside panel
5m(16.40ft.), 10m(32.81ft.), 20m(65.62ft.)
——
MR-J3BUS M-B
(Note-6)
• Q170MSCPU
MR-J4(W)- B/MR-J4(W)- B MR-J4(W)- B/
MR-J4(W)-
B LJ72MS15
• Q170MSCPU
MR-J3(W)- B/MR-J3(W)- B MR-J3(W)- B
• Long distance cable
30m(98.43ft.), 40m(131.23ft.), 50m(164.04ft.)
——
(Note-1): =Cable length (015: 0.15m(0.49ft.), 03: 0.3m(0.98ft.), 05: 0.5m(1.64ft.), 1: 1m(3.28ft.), 2: 2m(6.56ft.),
3: 3m(9.84ft.), 5: 5m(16.40ft.), 10: 10m(32.81ft.), 20: 20m(65.62ft.), 25: 25m(82.02ft.),
30: 30m(98.43ft.), 40: 40m(131.23ft.), 50:50m(164.04ft.))
(Note-2): Be sure to use the cable for forced stop input. The forced stop cannot be released without using it.
Cable for forced stop input is not attached to the Motion controller.
(Note-3): The manual pulse generator or incremental synchronous encoder that consumes less than 0.2[A] of
current can be connected to the internal I/F connector.
(Note-4): Be sure to use the power supply module within the range of power supply capacity.
(Note-5): 5VDC internal current consumption of shared equipments with PLC might be changed.
Be sure to refer to the MELSEC-Q series PLC Manuals.
(Note-6): Please contact your nearest Mitsubishi sales representative for the cable of less than 30m(98.43ft.).