4.1.4 Setting items for JOG data
The "JOG data" must be set to perform "JOG operation". The following are the setting
items of the "JOG data".
The "JOG data" are set commonly for each axis.
Refer to "CHAPTER 10 JOG OPERATION" for details of "JOG operation" and to
"Section 4.4 List of JOG data" for details of the setting items.
JOG data JOG operation
JOG. 1
JOG speed
JOG. 2
JOG ACC time
JOG. 3
JOG DEC time
JOG. 4
JOG direction flag
: Always set
: Setting not required (This is an irrelevant item, so the setting value will be ignored. If the value is the
default value or within the setting range, there is no problem.)
Checking the JOG data
JOG. 1
to
JOG. 4
are checked for the setting ranges when JOG operation is
started. At this time, an error occurs in the JOG data whose value has been set
outside the setting range. (For details, refer to "CHAPTER 13
TROUBLESHOOTING".)