7 - 1 7 - 1
MELSEC-Q
7 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL
CHAPTER 7 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL
This chapter describes sequence programs of the positioning control system using the
QD70.
7.1 Precautions for creating program
(1) System configuration
Unless otherwise specified in this section and later, the sequence programs
shown are those for the following system.
Refer to Section 7.2 for the applications of the devices used.
power
supply
module
Q
C
P
U
Q
D
7
0
Q
X
1
0
X/Y0 to X/Y1F
X20 to X2F
(2) Communication with QD70
There are two methods for communication with QD70 using the sequence
program: a method using an "intelligent function device" and a method using a
FROM/TO command.
When using the FROM/TO command for communication with QD70, change the
circuit incorporating the "intelligent function device" as follows.
(a) When the circuit uses the "intelligent function device" on the destination (D)
side of a MOV command, change the command to a TO command.
X21
MOVP0
U0\
G50
K1H0TOP K50
X21
0
K1
K1
Designated
value
at U0
Number of
write data (1)
Intelligent function device
Designated
value
at G50
(b) When the circuit uses the "intelligent function device" on the source(s) side
and the destination (D) side of a MOV command, change the command to a
FROM command and a TO command.
X15
0
MOVP
U6\
G1
U0\
G79
0
D100
K1
H0
FROMP K79
D100 K1H6TOP K1
X15 X0C
Set the same
device.
X0C
7