EasyManua.ls Logo

Mitsubishi QD70P4 - Page 57

Mitsubishi QD70P4
224 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4 - 18 4 - 18
MELSEC-Q
4 DATA USED FOR POSITIONING CONTROL
OPR. 5
Creep speed
Set the creep speed after near-point dog ON (the low speed just before stopping
after decelerating from the OPR speed).
The creep speed is set within the following range.
(
OPR. 4
OPR speed ) (
OPR. 5
Creep speed) (
Pr. 6
Bias speed at start)
Note) The creep speed is related to the detection error when using the OPR
method with zero signal, and the size of the collision if a collision occurs
during OPR using the stopper.
Set the "creep speed" to a value not more than "
OPR. 4
OPR speed". If
the "OPR speed" is exceeded, "the "Setting range outside creep speed"
error (error code: 914) will occur.
Set the "creep speed" to a value not less than "
Pr. 6
Bias speed at start".
If it is less than the "bias speed at start", the "Setting range outside creep
speed" error (error code: 914) will occur.
ON
V
OPR. 4
OPR. 5
Pr. 6
OPR control start
Near-point dog signal OFF
Z
ero signal
Bias speed at start
OPR speed
Creep speed
OPR. 6
ACC/DEC time at OPR
Set the time taken under OPR control to reach "
OPR. 4
OPR speed" from "
Pr. 6
Bias speed at start" or to reach "
OPR. 5
Creep speed" from "
OPR. 4
OPR
speed".
Pr. 6
OPR. 6
OPR. 6
OPR. 4
OPR. 5
t
V
t
V
OPR. 6
Pr. 6
OPR. 5
(When OPR method is other than "Stopper 3") (When OPR method is "Stopper 3")

Table of Contents