6. Discription of Display Screens
6-17
(e) SCHEDULE#
Fixes the method of how to select a schedule.
EXT. (NP): Select a schedule by closing a schedule-selecting
terminal on Rear Panel
EXT. (P) : Select a schedule by closing a schedule-selecting
terminal and a parity terminal on Rear Panel.
PANEL : Select a schedule on Front Panel.
Input a parity signal so that the total number of a closed schedule-selecting
terminal and a closed parity terminal may be odd.
(f) END SIG. TIME
Set the time period during which End signal or GOOD signal is output.
10/100ms: Outputs End signal for 10ms or 100ms.
HOLD : Outputs End or GOOD signal for the period during which
2ND STAGE terminal is closed. But if it is closed for 10ms
or less, the signals are output for 10ms. If it is longer than
10ms, they are output for the closed period of 2ND STAGE
terminal.
(g) MONITOR MODE
Set the mode of a displayed monitor value.
EXCLUDE SLOPE: Slope period not included.
INCLUDE SLOPE : Slope period also included.
(h) CALCULATION MODE
Set the way of calculating a monitored value.
NORMAL : Set NORMAL usually.
FAST : If the tact time is needed to shorten, the shorter calculation
time is obtained when FAST is set.
(i) LCD CONTRAST
Adjust the contrast of Screen.
Press +Key and then ENTER Key to make letters thinner.
Press +Key and then ENTER Key to make letters darker.