IPB-5000A
9. Time Chart
9-11
1) In the case of OFF or BI-DIRECTION at COMM CONTROL,
CALCULATION MODE
Display Screen
NORMAL FAST
SCHEDULE 360ms
310ms
MONITOR 205ms 155ms
COMPARATOR 380ms 330ms
ENVELOPE 515ms 465ms
PRECHECK 220ms 170ms
CONTROL 215ms 165ms
STATUS 205ms 155ms
2) In the case of DATA OUTPUT at COMM CONTROL,
CALCULATION MODE
COMM
SPEED
Display Screen
NORMAL FAST
SCHEDULE 485ms
435ms
MONITOR 330ms 280ms
COMPARATOR 505ms 455ms
ENVELOPE 640ms 590ms
PRECHECK 345ms 295ms
CONTROL 340ms 290ms
9600bps
STATUS 330ms 280ms
SCHEDULE 430ms 380ms
MONITOR 275ms 225ms
COMPARATOR 450ms 400ms
ENVELOPE 585ms 535ms
PRECHECK 290ms 240ms
CONTROL 285ms 235ms
19200bps
STATUS 275ms 225ms
SCHEDULE 400ms 350ms
MONITOR 245ms 195ms
COMPARATOR 420ms 370ms
ENVELOPE 555ms 505ms
PRECHECK 260ms 210ms
CONTROL 255ms 205ms
38400bps
STATUS 245ms 195ms
1-2 Setting
As same as in 1-5 Setting, firstly, weld current is supplied on the first
selected SCHEDULE No. and then on the consecutive 2 SCHEDULE No.’s
including the first selected No. in turn .
Weld current is supplied through the transformer selected at Transformer No.
(TR#) in each SCHEDULE Screen.
Note)
The values at the
tables show maximum
ones.
Note)
The values at
the tables show
maximum ones.