6. Discription of Display Screens
6-20
ERROR SETTING Screen
The signals output at the occurrence of an error (NG Signal/Caution Signal) can
be set item by item.
(a) OFF/ON
OFF : NG Signal is output.
The input of Start Signal is not accepted at the occurrence of
NG.
ON : Caution Signal is output.
The input of Start Signal is accepted even at the occurrence
of Caution.
(b) BACK
Displays STATUS (2/2) Screen of the previous page.
MISC Screen
(a) USER1 (1.00 – 9.99)
It is for testing. It cannot be used.
(b) DISPLACEMENT SENSOR STEP
Input the resolution of Displacement Sensor.
Ex.)
GS-1630A, GS-1613A, LGK-110: 1.0µm
ST1278 : 0.5µm