www.mobotix.com • sales@mobotix.com
Deactivating a camera's microphone may become necessary in order to protect the privacy
of persons at a workplace or for other reasons. You can permanently and irreversibly
deactivate the microphone in the dialog.
Caution
This even by MOBOTIX engi-
neers. Deactivating the microphone will also deactivate all features that use the
camera’s microphone.
If the camera's IP address is not known, you can start the camera with its factory IP
address. Section 3.2.6
Starting the Camera with the Factory IP Address
describes this
procedure in more detail.
All settings of the MOBOTIX camera can be permanently reset to the factory default settings.
This makes sense if you have, for example, obtained a camera without any information
or you would like to reset all settings after testing the camera. In order to perform this
procedure, you need to have access to the Administration menu of the camera (admins
group). Open to reset the camera to factory defaults.
Note
All defined users will be deleted and the admin password will be reset to the factory
default when you reset the camera using . If you want to maintain
existing users, use the method described in Section 3.2.6
Starting the Camera with the
Factory IP Address
..
In its default configuration, the camera's event control and video motion detection features
are not enabled. In order to activate event-controlled recording, open
and activate the Arming switch. Another method is to click the
soft key in the browser's user interface. The camera displays the video
motion detection window in the live image (dotted frame in the center) and the camera
automatically stores images as soon as the video motion window detects movements.
The microphone can be
irreversibly deactivated!
can also be reset
partially
If the dotted
rectangle in the live
image is visible, the
camera is armed